Moxa Technologies OnCell G3110 Quick Installation Manual
Moxa Technologies OnCell G3110 Quick Installation Manual

Moxa Technologies OnCell G3110 Quick Installation Manual

Oncell g3100 series
Hide thumbs Also See for OnCell G3110:

Advertisement

Quick Links

OnCell G3100 Series
Quick Installation Guide
Moxa Americas:
Toll-free: 1-888-669-2872
Tel:
1-714-528-6777
Fax:
1-714-528-6778
Moxa Europe:
Tel:
+49-89-3 70 03 99-0
Fax:
+49-89-3 70 03 99-99
Moxa India:
Tel:
+91-80-4172-9088
Fax:
+91-80-4132-1045
Edition 4.1, August 2016
Technical Support Contact Information
www.moxa.com/support
 2016 Moxa Inc. All rights reserved.
Moxa China (Shanghai office):
Toll-free: 800-820-5036
Tel:
+86-21-5258-9955
Fax:
+86-21-5258-5505
Moxa Asia-Pacific:
Tel:
+886-2-8919-1230
Fax:
+886-2-8919-1231
P/N: 1802031000016
*1802031000016*

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the OnCell G3110 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Moxa Technologies OnCell G3110

  • Page 1: Quick Installation Guide

    OnCell G3100 Series Quick Installation Guide Edition 4.1, August 2016 Technical Support Contact Information www.moxa.com/support Moxa Americas: Moxa China (Shanghai office): Toll-free: 1-888-669-2872 Toll-free: 800-820-5036 Tel: 1-714-528-6777 Tel: +86-21-5258-9955 Fax: 1-714-528-6778 Fax: +86-21-5258-5505 Moxa Europe: Moxa Asia-Pacific: Tel: +49-89-3 70 03 99-0 Tel: +886-2-8919-1230 Fax:...
  • Page 2: Package Checklist

    TCP/IP support, and can be configured over a network. Package Checklist Moxa’s OnCell G3110 Series is shipped with the following items. If any of these items is missing or damaged, please contact your customer service representative for assistance.
  • Page 3: Hardware Introduction

    Hardware Introduction Front Views OnCell OnCell G3110-HSPA/ Rear View G3110/G3150 OnCell G3150-HSPA Top View Bottom Views OnCell G3110/G3110-HSPA OnCell G3150/G3150-HSPA Side Views - 3 -...
  • Page 4: Reset Button

    Reset Button Press the Rest button continuously for 5 second to load factory defaults: Use a pointed object, such as a straightened paper clip or toothpick, to press the reset button. This will cause the Ready LED to blink on and off. The factory defaults will be loaded once the Ready LED stops blinking (after about 5 seconds).
  • Page 5 Adjustable pull high/low resistor for RS-485 Port DIP switches on the bottom of the OnCell G3100 are used to set the pull high/low resistor value for each serial port. Pull High Pull Low Terminator 1 KΩ 1 KΩ 120 Ω 150 KΩ...
  • Page 6: Specifications

    Pin Assignments and Cable Wiring DB9 Male Port Pinouts Note that the OnCell G3110 only supports RS-232. The RS-422/485 pin assignments only apply to the OnCell G3150. DB9 Male RS-232 – 4W/2W RS-485/RS-422 (Terminal Block) Pinouts RS-422/485 RS-485 4-wire 2-wire TxD+(B) –...
  • Page 7: Serial Interface

    Cellular Interface (for OnCell G3110-HSPA & G3150-HSPA) Data Rate UMTS (DL: 384 Kbps, UL: 384 Kbps) HSPA (DL: 14.4 Mbps, UL: 5.67 Mbps) Standard Compliance GSM/GPRS/EDGE/UMTS/HSPA Band Selection Five band 800/850/AWS/1900/2100 MHz Quad-band 850/900/1800/1900 MHz Tx Power 1 watt GSM1800, 2 watt GSM900, 0.25 watt UMTS/HSPA...

This manual is also suitable for:

Oncell g3110-hspaOncell g3150Oncell g3150-hspa

Table of Contents