Check IGN
Status
Power Management 
 Power‐off delay time is selectable by Software to disable and enable in 0‐255 
minutes   
 Ignition On/Off status detectable by SW   
 If the ignition is off and the system is still on after 3 Sec, FLEETPC‐8‐I7B‐POE will shut 
down automatically.   
 If the ignition is turned on again and the power‐off delay is in progress, FLEETPC‐8‐
I7B‐POE will cancel the delay function and will continue to operate normally. 
 If the ignition is turned on again and the power‐off delay ended, FLEETPC‐8‐I7B‐POE 
will shut down completely will power‐on again automatically. 
 
 
 
User's Manual
IGN off (Low)
Power Ignition Shutdown Procedure 
Delay Time Off
Delay 3 Sec
Check Delay Time
On / off
Delay Time On
0-255 Minutes Setting
by BIOS or Software
5.0 System Resource
Shutdown from
IGN off
OS Shutdown System
3 sec later
System Power off