6| Maintenance

6.1 Preparation

6.2 Work to be carried out

Oil change: In principle, an oil change is not mandatory if the system is correctly manufactured
and operated. However, based on decades of experience we recommend that the following oil
change/service work is carried out:
-
First oil change during the first maintenance of the vehicle.
-
Then after every 5,000 operating hours, though no more than 3 years, clean the oil strainer
at the same time. If necessary, also empty the oil reservoir at the shaft seal.
D
Annual checks: Oil level, tightness of the compressor, running noise, pressures, temperatures,
GB
function of auxiliary devices such as checking the capacity control.
F

6.3 Recommended spare parts

I
FK50 / ...
TR
CN
Designation
Set of gaskets
Valve plate kit
Set of shaft seals
Oil SP 46, 1 litre
Oil SE 55, 1 litre
Only use genuine GEA spare parts!

6.4 Integrated decompression valves

The valves are fundamentally maintenance-free.
However, constant leakage can occur after repeated blowing off due to abnormal operating conditions.
This leads to reduced performance and increases the compressed gas temperature. In this case check
the valves and replace as necessary.
18
WARNING! Before starting any work on the compressor:
Switch off the compressor and secure it to prevent a restart.
Relieve compressor of system pressure.
Prevent air from infiltrating the system!
After maintenance has been performed:
Connect safety switch.
Evacuate compressor.
Release switch lock.
460 N, TK
555 N, TK
Art. No.
80243
660 N, TK
775 N, TK
830 N
980 N
Art. No.
80231
80244
80023
02279
02282
460 K, 555 K
660 K, 775 K
830 K, 980 K
Art. No.
80089