7 | Maintenance

7.1 Preparation

7.2 Work to be carried out
Oil change: In principle, an oil change is not mandatory if the system is correctly manufactured
and operated.
However, based on decades of experience we recommend that the following oil change/service
work is carried out:
-
First oil change during the first maintenance system.
-
Then after every 10,000 – 12,000 operating hours, though no more than
3 years, cleaning oil and suction filter at the same time.
D
Annual checks: Oil level, tightness, running noise, pressures, temperatures, function of auxiliary
devices such as a oil sump heater, pressure switch.
GB
F

7.3 Spare parts recommendation

E
HG22e / ...
Designation
Set gaskets
Valve plate set
Piston/connecting
rod set
Connecting rod set
Only use original GEA spare parts!

7.4 Accessories

Accessories available can be found on the Internet at www.gea.com
22
WARNING! Before starting any work on the compressor:
Switch off the compressor and secure it to prevent a restart.
Relieve compressor of system pressure.
Prevent air from infiltrating the system!
After maintenance has been performed:
Connect safety switch.
Evacuate compressor.
Release switch lock.
125-4(S) A
Ref. No.
80305
80302
160-4(S) A
Ref. No.
80590
80306
80303
08422
190-4(S) A
Ref. No.
80306
80304

Advertisement