Epson S5U1C17001H User Manual page 11

Cmos 16-bit single chip microcomputer
Hide thumbs Also See for S5U1C17001H:
Table of Contents

Advertisement

Selecting either ICD mode or Flash programmer mode (SW2 and SW3)
OPEN (↑)
OPEN (↑)
In ICD mode, the debugger on the PC controls the S5U1C17001H to execute the debug commands. (See Chapter 5.)
In Flash programmer mode, the S5U1C17001H operates as a standalone Flash programmer. (See Chapter 6.)
Selecting the DSIO signal level (SW4 and SW5)
OPEN (↑)
OPEN (↑)
The target operating voltage should be input to Pin 4 on the Flash programming power supply connector.
enabling the connection test (SW6)
The connection test is a communication diagnostic feature at start up of the debugger.
Setting firmware update mode (SW7)
When SW7 is set to ON, a connection between the S5U1C17001H and the debugger can be established even if a
target is not connected. See Chapter 7, "Firmware Update," for how to update the firmware.
enabling voltage output for Flash programming (SW8)
note: The S5U1C17001H is equipped with a 7-V Flash programming power supply with output capaci-
ties of 200 mA. Note, however, that its usage depends on the S1C processor. Be sure to avoid us-
ing this power supply for the S1C processor (do not set SW8 of the DIP switch to ON) if its techni-
cal manual does not describe the usage of the Flash programming power supply, as the chip may
be destroyed due to overvoltage.
BrK In pin
In ICD mode, if a low-level signal is input to this pin when the target program is being executed, the target
program execution is suspended. After a low level is input to the BRK IN pin, a break will occur after a few in-
structions have been executed.
In Flash programmer mode, inputting a low level to this pin has the same function as pressing the RESET/
START switch (it starts erasing/programming/verification).
note: The voltage to apply to the BRK IN pin must be 0 V for low level and 3.3 V or open for high level.
The BRK IN pin is always pulled up to 3.3 V.
GnD pin
Connect this pin to the GND level (0 V).
S5U1C17001H USer ManUal
(ICD MInI Ver. 1.0)
Downloaded from
Elcodis.com
electronic components distributor
SW2
SW3
OPEN (↑)
ICD mode (default)
ON (↓)
OPEN (↑)
Flash programmer mode
ON (↓)
Flash programmer mode
ON (↓)
ON (↓)
Flash programmer mode
SW4
SW5
OPEN (↑)
3.3 V (default)
ON (↓)
1.8 V
ON (↓)
Voltage (1.0 to 5.0 V) input from the target
SW6
OPEN (↑)
Omitt connection test (default)
ON (↓)
Execute connection test
SW7
OPEN (↑)
OFF (default)
ON (↓)
ON
SW8
OPEN (↑)
OFF (default)
ON (↓)
ON
Table 3.1.2 SW2 and SW3 Settings
Erase → program
Verify
Erase → program → verify
Table 3.1.3 SW4 and SW5 Settings
Table 3.1.4 SW6 Settings
Table 3.1.5 SW7 Settings
Table 3.1.6 SW8 Settings
ePSOn
3 naMe anD FUnCTIOn OF eaCH ParT
Setting
Setting
Setting
Setting
Setting
5

Advertisement

Table of Contents
loading

Table of Contents