⑯ Upper/lower flap control
Upper/lower flap control
Stop at fixed position
Stop at any position
Select the item.
Stop at fixed position
The upper/
lower flap can be set to stop at one of four
positions.
Stop at any position
The flap can
be set to stop at any position immediately
after operating the R/C switch.
⑲ Auto-restart
Auto-restart
Enable
Disable
Select the item.
If the unit stops during operation,
Enable It returns to the state before
the power failure as soon as the power
supply is restored (After the end of the
primary control at the power on).
Disable It stops after the restoration of
power supply.
⑰ Left/right flap control
Left/right flap control
Fixed position stop
Stop at any position
Back
Select the item.
Fixed position stop
flap can be set to stop in eight different
patterns.
Stop at any position
be set to stop at any position immediately
after operating the R/C switch.
⑳ Auto temp setting
Auto temp setting
Enable
Disable
Back
Select the item.
Enable Auto can be selected on the
room temperature setting screen.
Disable Auto selection switch will not
be displayed on the room temperature
setting screen.
Back
The left/right
The flap can
Back
−20−
⑱ Ventilation setting
Ventilation setting
Disable
Interlocking
Independent
Select the item.
Set this when a ventilation device is
connected.
Disable
No ventilation device is
connected.
Interlocking Ventilation is interlocked
with the Run/Stop of air conditioner and
operate the Ventilation output.
Independent If the ventilation is selected
from the menu, only the ventilation device
is operated or stopped independently.
Auto fan speed
Auto fan speed
Enable
Disable
Select the item.
Enable Auto can be selected on the
fan speed setting screen.
Disable Auto selection switch will not
be displayed on the fan speed setting
screen.
Back
Back