Setting Inspection Conditions
Entering Monitor Mode from Run Mode
2-4-7-2
Test Measurement
SeeAlso
CHECK
CHECK
TwoCamera
1.
Move the cursor to RUN and press the ENT Key. The mode selections will
be displayed.
0.Scn 0
MON
SET
MON
RUN
SYS
TOOL
SAVE
2.
Select MON to enter Monitor Mode.
Use the following procedure to execute measurements according to the condi-
tions set for the scene currently displayed. The test is completed internally by
the F160 and the measurement results are not output via serial or parallel
interfaces. The measurement commands can be input, however, via serial or
parallel interfaces.
Refer to the Communications Reference Manual for details.
1.
Press the TRIG Key on the Console or input the measurement command
from an external device.
Overall judgement
0.Scn 0
MON
Measurement will be executed and the measurement results displayed on
the screen.
Measurement Time
The time taken for the measurement will be displayed.
Compared to freeze displays, the measurement time for through displays will
be up to 20 ms longer for frames and 10 ms longer for fields when F160-S1
Cameras are used.
Overall Judgement
The overall judgement will be NG if there is an NG in one or more measure-
ment regions, position compensations, or output expressions.
The items to be included in the overall judgement can be set individually. Refer
to page 315.
If the camera mode is Camera 0+1, switch between Camera 0 images and
Camera 1 images by pressing the Up/Down Keys. Refer to page 33.
---- ---ms
Freeze
Measurement time
OK
67ms
Freeze
Section 2-4
59