CS-MVG103KE / CU-MVG153KE
11 Installation Information
11.1. ATTACHED ACCESSORIES
11.2. SELECT THE BEST LOCATION
11.2.1. INDOOR UNIT
· There should not be any heat source or steam near the unit.
· There should not be any obstacles blocking the air circulation.
· A place where air circulation in the room is good.
· A place where drainage can be easily done.
· A place where noise prevention is taken into consideration.
· Do not install the unit near the door way.
· Ensure the spaces indicated by arrows from the wall, ceiling, fence or other obstacles.
· Indoor unit of this room air conditioner shall be installed on the wall in a height of at least 2.3m.
11.2.2. OUTDOOR UNIT
· If an awning is built over the unit to prevent direct sunlight or rain, be careful that heat radiation from the condenser is not
obstructed.
· Ensure that no animals or plants can be affected by the hot air discharged.
· Keep the spaces indicated by arrows from wall, ceiling, fence or other obstacles.
· Do not place any obstacles which may cause a short circuit of the discharged air.
· If piping length is over the common length, additional refrigerant should be added as shown in the table.