Power Monitor Display; Remote Control Signal Receiving Sound On/Off - Panasonic CS-MVG103KE Service Manual

Table of Contents

Advertisement

CS-MVG103KE / CU-MVG153KE

8.17. POWER MONITOR DISPLAY

Power Monitor LED lights on when the compressor is in operation. The number of the LED lights on is in accordance to the Comp.
Operation Frequency Command Number.
Display
Cooling & Soft Dry Indication Comp.
Operation Frequency Command Number
Heating Indication Comp. Operation
Frequency Command Number

8.18. REMOTE CONTROL SIGNAL RECEIVING SOUND ON/OFF

· Press the AUTO button for 10 seconds or longer to switch off the signal receiving sound.
· Press the AUTO button for 10 seconds or longer again to switch on the signal receiving sound.
A
A, B
1-4
5-6
1-3
4-5
34
A, B, C
A, B, C, D
7-8
9
6-7
8-9
A, B, C, D, E
10-15
10-15