Intercharacter, Interfunction, and Intermessage Delays

Some terminals drop information (characters) if data comes through too quickly.
Intercharacter, interfunction, and intermessage delays slow the transmission of
data, increasing data integrity.

Intercharacter Delay

An intercharacter delay of up to 5000 milliseconds (in 5ms increments) may be
placed between the transmission of each character of scanned data. Scan the
Intercharacter Delay bar code below, then scan the number of 5ms delays, and
the
To remove this delay, scan the Intercharacter Delay bar code, then set the number
of delays to 0. Scan the
page 225.
Note: Intercharacter delays are not supported in USB serial emulation.

User Specified Intercharacter Delay

An intercharacter delay of up to 5000 milliseconds (in 5ms increments) may be
placed after the transmission of a particular character of scanned data. Scan the
Delay Length bar code below, then scan the number of 5ms delays, and the
bar code from the
Character to Trigger Delay bar code, then the 2-digit hex value for a printable
character to trigger the delay (see
Orbit 7120plus/7190g User Guide
Save
bar code from the
Programming Chart,
Delay Length
Programming Chart,
Prefix
Scanned Data
1
2
3
Intercharacter Delay
Intercharacter Delay
Save
bar code from the
beginning on page 225. Next, scan the
Lower ASCII Reference Table
beginning on page 225.
Suffix
4
5
Programming Chart,
on page 215.
Character to Trigger Delay
beginning on
Save
)
63