Partial Sequence

If an output sequence operation is terminated before all your output sequence cri-
teria are met, the bar code data acquired to that point is a "partial sequence."
Scan Discard Partial Sequence to discard partial sequences when the output
sequence operation is terminated before completion. Scan Transmit Partial
Sequence to transmit partial sequences. (Any fields in the sequence where no data
match occurred are skipped in the output.)

Require Output Sequence

When an output sequence is Required, all output data must conform to an edited
sequence or the scanner will not transmit the output data to the host device. When
it's On/Not Required, the scanner will attempt to get the output data to conform to
an edited sequence but, if it cannot, the scanner transmits all output data to the
host device as is.
When the output sequence is Off, the bar code data is output to the host as the
scanner decodes it. Default = Off.
Note: This selection is unavailable when the Multiple Symbols Selection is turned on.
56
Transmit Partial Sequence
Required
*Off
* Discard Partial Sequence
On/Not Required
Orbit 7120plus/7190g User Guide