4.1 Mechanical and Environmental Specifications
Ensure that the installation site can accommodate the mechanical and environmental
specifications of the IDU.
specifications for the iDirect 3000 series™ Satellite Router.
Table 5
Mechanical and Environmental Specifications
Category
Dimensions
Weight
Airflow
Ambient Temperature
Operational:
Temperature Gradient
Relative Humidity
Operational:
Altitude
Operational Vibration
(10 minutes per axis)
Operational Shock
18
Table 5
details the mechanical and environmental
Description
2.0 (H) x 11.5 (W) x 9.5 (D) inches
3.75 pounds (1.7 Kg)
natural convection cooling
32°F to 113°F (0°C to 45°C) at 10,000 Feet
32°F to 122°F (0°C to 50°C) at Sea Level
Storage:
-30°F to 176° F (-34°C to 80°C)
0.5°C/min
0 to 90% non-condensing
Storage:
5 to 93%
≤ 10,000 feet (3048m)
Operating:
≤ 30,000 feet (9144m)
Storage:
The IDU chassis will remain operational when exposed to 0.21
grms with the following profile:
Frequency
5 to 350 Hz
350 to 500 Hz
500 Hz
The IDU chassis shall remain operational when exposed to 10g,
10ms half sine on x, y, z axis.
iDirect 3000 series™ Satellite Router Installation and Safety Manual
Slope
PSD
0
0.0001 g2/Hz
-6 dB/octave
0
0.00005 g2/Hz