2-5.
UNCAL
Error
Codes
CODE
DESCRIPTION
000 000 000
=
No UNCAL conditions
002 000 000
=:
FM
Dev/0M
>
(freq
-150
kHz)
*004 000 000
=
Excess
FM
Dev/0M,
main
or
reference PLL unlocked
*010 000 000
= FM DAC at
full scale
200 000
000
Multiple COMP memory checksum errors.
See
Compensation
Memory Status
in
Section
2.
*000 010 000
=
Main
or
reference PLL unlocked
000 000
001
s
Level vernier
> 12
dB
below bottom
of
range
000 000 002
-
Peak amplitude
>
+16 dBm
for
freq
<
1050 FWz
or
>
+13 dBm
for
freq
>=
1050 MHz
*000 000 004
a
Amplitude unleveled
*000 000 010
a
Fixed-range
level
vernier
at 0
*000 000 020
s
Fixed-range
Level
vernier
at
full scale
*000 000 040
-
RPP
tripped
000 000 100
a
Level
<
-137 dBm
000 000 200
=
Level correction disabled
*000 000 400
= RF
off
Flashing codes (denoted
by
*)
indicate abnormal
operation
or
aberrated
output
.
Non-
-flashing codes indicate operation outside specified
range.
Table
2-6.
REJect
ENTRY
Codes
CODE
DESCRIPTION
000 000 000
=
No
rej
ected entries
001
000 000
s:
FM
Oev/0M
not
between
0
and
400
kHz
(40.0 kHz with Option -651)
002 000
000
=
FM
Dev/0M Step
not
between
0
and 400 kHz
(40.0 kHz with Option -651)
004
000 000
AM Depth not between
0
and
99%
010 000
000
AM Depth Step not
between
0
and 99%
020 000 000
=
IEEE-488 command syntax error
040 000
000
IEEE-488
input value out
of
range
100 000
000
= MEC
compensation PROM error
200 000 000
=
IEEE edit or step
operation beyond allowed
range
400 000 000
=
Invalid frequency
in
COMP memory
000
001
000
=
Frequency
not
between 100 kHz
and
2100 Miz
000 002 000
=
COMP switch
not
enabled
or
low-rate
FM
option
not
disabled
000 004
000
=
Frequency
Step not
between
0 and 2100 MHz
000 010 000
=
COMP data may
not
be stored
if
procedure incomplete
000 020
000
=
Invalid compensation command
000 040 OOQ
=
Invalid memory location
000 100 000
=
Invalid data
in
memory
000 200 000
8
Special function not
allowed
000 400
OQO
=
COMP data range error
000 000
001 B
,
Output amplitude
not
between
10 nV and
1.58V
000 000 002
B
Insufficient resolution
for
units conversion
000
000
004
=
Units conversion
to
volts
not
allowed with reference
in
volts
000 000 010
s
Units conversion to
dB not
allowed with reference
in
volts
000 000 020
s
Amplitude Step
not
between
0
and
164 dB
or
0 and 1999V
000 000 040
=
Units conversion
of A^npLitude or
FM/0M Step
not
allowed
000 000 100
=
Amplitude
or FM/0M step and
current display
not in same
units
000 000 200
s
COMP data from IEEE-488
out of
range
or edit
beyond COMP
limits
000 000 400
a
Internal compensation data transfer error
2.
Entering
the step
size
from IEEE-488
does not
select
the step function.
For
example,
"FS 10MZ"does
not
select
the step
function;
"FD"
or
"FU"must
be used
to select
the
frequency
step function.
The
generic step
up/down commands "SU"
and
"SD"may
be used
to step
the current
step
function.
3.
If
the
Low-Rate
FM
option
is
installed,
the
range of
FM
deviation steps
is
0 to 40.0
kHz, and
the
range
of
0M
deviation
steps
is
0 to 4.00
rad.