Download Print this page

Fluke 6062A Instruction Manual page 29

Rf generators

Advertisement

SPECIAL FUNCTION
OPERATION
GO
Clear
all special functions.
02
Initiate
self tests.
03
Display
test.
See
Section
3.
04
Key
test.
See
Section
3.
07
Set SRQ.
08
Reset
SRQ.
09
Display software revision
level.
Information appears
in
the MODULATION
and
FREQUENCY display fields
for
5
seconds
or
until
another
key
is
pressed.
10
Display IEEE-488 mode
and address
11
Display self-test
results. Zeros
in
the display fields indicate
that the self tests have passed. See
Section
4.
12
Turn on displays.
13
Turn off
all
displays. ALL other functions still operate.
14
Initialize memory
Locations to instrument Preset
State.
Sto
?
appears
in
the
FREQUENCY display field
for
5
seconds.
If
during this time, the CST03 key
is
Pressed, all memory Locations are initialized.
15
Latch
test. See Section
4.
16
Display option
loading. See
Interrogate Commands
in
this section.
17
Initiate self
test with RF on.
See Section 4.
20
Disable Relative Frequency.
See
Relative Function
in
this section.
21
Enable Relative Frequency.
See
Relative Function
in
this section.
30
Disable Relative Amplitude.
See
Relative Function
in
this section.
31
Erable Relative Amplitude.
See
Relative Function
in
this section.
40
Disable Internal
Pulse
Modulation. See Modulation Entry
in
this
section
41
Enable Internal
Pulse Modulation. See
Modulation Entry
in
this
section
50
Select dBm Amplitude Display Mode. See Amplitude Units Selection
in
this section.
51
Select dBmV Amplitude Display Mode. See Amplitude Units Selection
in
this section.
52
Select
dBuV Amplitude Display
Mode. See
Amplitude Units Selection
in
this section.
60
Disable
DC
AM mode.
See
Modulation Entry
in
this section.
61
Enable
DC
AM mode.
See
Modulation Entry
in
this section.
70
Set
repeat
rate for EDIT and STEP
keys
to
medium.
71
Set
repeat rate
for
EDIT and STEP keys to fast.
72
Set
repeat
rate for EDIT and STEP
keys
to slow.
75
Display Compensation Memory status.
See
Section
4.
76
Repair Compensation Memory Errors. See Section
4.
77
Load
FM
MEC PROM data into
Compensation
Memory.
See
Section
4
78
Load Output
MEC PROM
data into
Compensation
Memory.
See
section
4.
79
Load Attenuator
MEC
PROM data into
Compensation
Memory.
See
section
4.
80
Enable Amplitude correction. Normal operation.
81
Disable Amplitude correction.
RF
output
Level
may be up
to 12 dB
low.
82
Disable attenuator correction. Useful
as
a
troubleshooting
tool. RF input to attenuator
is
flat.
83
Program alternate
24 dB
attenuation.
See
Section
4.
84
Program alternate
24 dB
attenuation.
See
Section
4.
85
Program alternate
24 dB
attenuation.
See
Section
4.
86
Program alternate
24 dB
attenuation.
See
Section
4.
90
Disable Amplitude
Fixed Range. See
Amplitude Fixed Range
in
this section-
91
Enable Amplitude
Fixed Range. See
topLitude Fixed Range
in
this section.
95
Initiate
FM
Keyboard Compensation Procedure.
See Section 4E.
96
Initiate Output Keyboard Compensation Procedure.
See
Section
4E.
97
Initiate Attenuator Keyboard Compensation Procedure.
See
Section
4E.
98
Initiate Output
with Default
Attenuator
Data
Keyboard
Compensation
Procedure, See
Section
4E.

Advertisement

loading