Download Print this page

Fluke 6062A Instruction Manual page 11

Rf generators

Advertisement

DISTORTION
INTRODUCTION
1-1.
6062A
Synthesized
RF
Signal
Generator
Specifications
(con!)
<1,5% total harmonic
distortion
(THD)
to
3CK AM, <3%
THD
to 70%
AM,
<5% THD
to 90% AM
for
frequencies
of
1
to
1049.99999 MHz
and
peak amplitude
<
+13
dBm.
<3%
THD to
70% AM,
and <5% THD to 90%
AM
for
frequencies
of
1050
to 2100
MHz
and
peak amplitude
<
+13 dBm.
<3%
THD
to 30% AM, <5%
THD to
70% AM,
and <7%
THD
to 90% AM for
frequencies
of 0.1
to
.99999 MHz
and peak
amplitude
<
+13
dBm.
BANDWIDTH
(3
dB)
20
Hz
to
50 kHz.
DC
to 50 kHz by
special function.
(Note
valid
for RF
frequency
- Mod
frequency >150
kHz)
INCIDENTAL
FM
<0.3
fm for
internal rates, 30%
or less
AM,
and frequencies from
0.1
to
1049.99999
MHz.
<0.6
fm for
internal rates, 30%
or less
AM,
and frequencies from 1050 to
2100
mz.
FREQUENCY MODULATION
(3-Digit Display)
DEVIATION RANGES
MAXIMUM DEVIATION
Mod Rate
fm
>,2 kHz
fm
<,E kHz
... 0
to
999
Hz,
1
to
9.99
kHz, 10 to
99.9
kHz, and 100
to 400 kHz.
Max Dev
RF
Frequency
400 kHz
200 kHz
100 kHz
200 kHz
1050 to 2100
Mhz
512 to
1049.99999
MHz
245 to
511.99999 Mhz
0.1
to 244.99999 Mhz
lower
of
above
or;
2
fm fo
245 to
2100 MHz
2
fm(fo+800)
0.1
to 244.99999 MHz
Where:
fm
=
mod
frequency
in
kHz
fo ® RF
frequency
in
MHz
Deviation
is in kHz
Specs apply where:
RF
Frequency
-
Dev
>150
kHz
RF
Frequency
"
Mod Rate >150 kHz
RESOLUTION
3
digits.
ACCURACY
+
(7% + 10 Hz)
for
rates
of
0,3 to
20 kHz. Does not
include effects
of
Residual
FM.
1-7

Advertisement