Estun pronet series User Manual page 64

Ac servo
Table of Contents

Advertisement

Step
5
JOG Mode Operation (Fn002)
Step
Display after operation
1
2
3
4
5
6
7
Note:
The servomotor's rotation direction depends on the setting of parameter Pn001.0 (Direction Selection).
The example above describes operation with Pn001.0 in the factory setting.
Description
Panel operator
MODE key
INC or DEC key
ENTER key
MODE key
INC or DEC key
MODE key
ENTER key
- 62 -
ProNet Series AC Servo User' s Manual
Check Method and Remarks
Use the panel operator to operate the servomotor with
utility function Fn002 (JOG Mode Operation)Check that
the servomotor rotates in the forward direction by pressing
the INC key, and reverse direction by pressing the DEC
key.
The operation is completed when the operation is
performed as described below and the alarm display does
not appear.
Complete the Fn002 (JOG Mode Operation) and turn OFF
the power.
For the operation method of the panel operator, refer to
Chapter 5 Panel Operator
The servomotor speed can be changed using the Pn305
(JOG Speed).The factory setting for JOG speed is
500rpm.
Description
Press the MODE key to select the function
mode.
Press the INC key or DEC key to select
Fn002.
Press the ENTER key, and the servomotor will enter
JOG operation mode.
Press the MODE key. This will turn ON the power to
the servomotor.
The servomotor will run in forward direction when INC
key is pressed or in reverse direction when DEC key
is pressed. The servomotor will operate as long as the
key is pressed.
Press the MODE key. This will turn OFF the power to
the servomotor.
Press the ENTER key to return to the Fn002 display
of the utility function mode. Now, the servo drive is
OFF.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents