Estun pronet series User Manual page 32

Ac servo
Table of Contents

Advertisement

Single-phase 100V ProNet-04B /Single-phase 100V ProNet-E-04B
Molded-case Circuit Breaker
Surge Protector
External regenerator resistor
Single-phase 100V ProNet-08B /Single-phase 100V ProNet-E-08B
Molded-case Circuit Breaker
Surge Protector
External regenerator resistor
Notes:
When single-phase 100VAC is provided for main circuit on rated speed, instantaneous peak torque≤4.78 N.m.
When three-phase 100VAC is provided for main circuit on rated speed, instantaneous peak torque≤7.16 N.m.
L1
L2
Single-phase 100~120V
+10%
(50/60Hz)
-15%
1 Ry
Noise Filter
Power OFF Power ON
1 Ry
1 KM
Magnetic Contactor
L 1
L2
1
2
L 1 C
L2C
B1
B1
B2
B2
B3
B3
Ground Terminal
L1
L2
+10%
Single-phase 100~120V
(50/60Hz)
-15%
1 Ry
Noise Filter
Power OFF Power ON
1 Ry
1 KM
Magnetic Contactor
L 1
L2
1
2
L 1 C
L2C
B1
B1
B2
B2
B3
B3
Ground Terminal
- 30 -
ProNet Series AC Servo User' s Manual
1PL (Servo Alarm Display)
1 KM
1SUP
Be sure to connect a surge suppressor to the
excitation coil of the magnetic contactor and relay.
U
V
W
CN2
1 Ry
+24 V
7
ALM+
8
ALM-
1D
0 V
1PL (Servo Alarm Display)
1 KM
1SUP
Be sure to connect a surge suppressor to the
excitation coil of the magnetic contactor and relay.
U
V
W
CN2
1 Ry
+24 V
7
ALM+
8
ALM-
1D
0 V
Servodrive
A(1)
B(2)
M
C(3)
D(4)
Encoder
PG
Servodrive
A(1)
B(2)
M
C(3)
D(4)
Encoder
PG

Hide quick links: