3. External regenerative resistor for ProNet-02A~04A/ProNet-E-02A~04A is provided by customer, the model of 60W,
50Ωresistor is recommended.
4.Change Pn521.0 from "1" to "0" when using the external regenerative resistor in ProNet-02A~04A/ProNet-E-02A~04A
servo drives.
Three-phase 200V ProNet-08A~50A
·
Molded-case Circuit Breaker
External Regenerator Resistor
Three-phase 400V ProNet-10D~75D
Molded-case Circuit Breaker
External Regenerator Resistor
L1
L2
L3
+ 10%
Three-phase 200~230V
- 15%
Surge Protector
Noise Filter
Power OFF
Power ON
1 KM
Magnetic Contactor
L 1
L2
Series Servodrives
L3
1
2
L 1 C
L2C
B1
B1
B2
B2
B3
B3
Ground Terminal
L1
L2
L3
+ 10%
Three-phase 380~440V
- 15%
Surge Protector
Noise Filter
Power OFF Power ON
1 KM
Magnetic Contactor
L 1
L2
Series Servodrives
L3
1
2
24V
24VDC Power Supply
GND
B1
B1
B2
B2
B3
B3
Ground Terminal
ProNet Series AC Servo User' s Manual
/
Three-phase 200V ProNet-E-08A~50A
(50/60Hz)
1 Ry
1PL (Servo Alarm Display)
1 KM
1 Ry
1SUP
Be sure to connect a surge suppressor to the
excitation coil of the magnetic contactor and relay. .
ProNet
U
V
W
CN2
7
ALM+
8
ALM-
/
Three-phase 400V ProNet-E-10D~50D
(50/60Hz)
1 Ry
1PL (Servo Alarm Display)
1 KM
1 Ry
1SUP
Be sure to connect a surge suppressor to the
excitation coil of the magnetic contactor and relay. .
ProNet
U
V
W
CN2
1 Ry
7
ALM+
8
ALM-
1D
- 28 -
Servomotor
A(1)
B(2)
M
C(3)
D(4)
Encoder
PG
+24 V
1 Ry
1D
0 V
Servomotor
A(1)
B(2)
M
C(3)
D(4)
Encoder
PG
+24 V
0 V