Mitsubishi Electric MELSERVO-J4 Instruction Manual page 26

General-purpose ac servo amplifier
Hide thumbs Also See for MELSERVO-J4:
Table of Contents

Advertisement

1. TROUBLESHOOTING FOR SERVO AMPLIFIER (DRIVE UNIT)
Alarm No.: 10
Name: Undervoltage
Alarm content
Detail
Detail name
No.
10.2
Voltage drop in
(7) The servo amplifier is
the main circuit
power
(8) For the drive unit, the
The voltage of the control circuit power supply has dropped.
The voltage of the main circuit power supply has dropped.
Cause
Check the bus
malfunctioning.
voltage value.
Replace the converter
converter unit is
unit, and then check
malfunctioning.
the repeatability.
Check method
Check result
The bus voltage is
less than the
prescribed value
although the voltage
of the main circuit
power supply is
within specifications.
200 V class: 200 V
DC
400 V class: 380 V
DC
100 V class: 158 V
DC
48 V DC setting:
24 V DC setting:
It is not repeatable.
1 - 19
Action
Replace the servo
amplifier.
35 V DC
15 V DC
Replace the
converter unit.
Target
[A]
[B]
[WB]
[RJ010]

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents