Mitsubishi Electric MELSERVO-J4 Instruction Manual page 164

General-purpose ac servo amplifier
Hide thumbs Also See for MELSERVO-J4:
Table of Contents

Advertisement

4. DRIVE RECORDER
Signal name
CSON
SON
EMG
EM2/EM1
ALM2
INP
MBR
RD
STO
IPF
This indicates status of the servo-on signal from the controller.
This Indicates the SON status of the external input signal.
This indicates status of the emergency stop input.
This Indicates the EM2/EM1 status of the external input signal.
This will turn on when an alarm is detected in the servo amplifier. This changes faster
than ALM of the external output signal.
This indicates INP status of the external output signal.
This indicates MBR status of the external output signal.
This indicates RD status of the external output signal.
This Indicates the STO status of the external input signal.
This will turn on when the control circuit power becomes instantaneous power failure
status.
Description
4 - 9
Unit

Hide quick links:

Advertisement

Table of Contents
loading