4.11 FAULTS DISPLAY

Installation, service and maintenance may only be carried out by a
certified contractor. The following table lists the fault codes and their
remedies .

Display

E01
E02
E03
E04
E05
E06
E07
E08
E09
E10
E11
4.11.1 DISPLAY
Display
HOT
COLD
www.jouleuk.co.uk
Description
Fault in the temperature sensor at the top of the cylinder
Temperature sensor for air inlet not working
Temperature in cylinder > 80 °C
NTC temperature sensor (evaporator plates) not working
Setting buttons hold down for longer than 30 seconds .
• System emptied incorrectly
• Water shortage (> 12h)
• Fault in the pump
• Resistor not working
• High limit safety cut-out not working
• Temperature of high limit safety cut-out set to a lower
value than the appliance
• Fault in the fan
• Pressure loss in the pipes
• Leaks in refrigerant circuit
• Fault in the compressor
• Expansion valve not working
• Drying filter not working
Description
Supply air temperature > 35 °C
Fault in the temperature sensor
Remedy
Notify certified contractor
Notify certified contractor
Notify certified contractor
If the problem persists after pressing "OK",
notify a certified contractor.
Notify certified contractor
Release buttons
Notify certified contractor
Notify certified contractor
Clear the fault Notify certified contractor
Notify certified contractor
Notify certified contractor
Remedy
System stops automatically in the "Heat
pump" operating mode if the air inlet tem-
perature is below -10 °C or above 35 °C.
General operating conditions are checked
on an hourly basis .