Page 1
HEATBANK operating and installation manual www.jouleuk.co.uk...
Page 2
Please read the installation instructions before installing the appliance! Please read the operating instructions before commissioning the appliance! Please observe the safety instructions in the operating instructions! The installation location must meet the requirements for sufficient ventilation! Installation must only be carried out by an authorized contractor! www.joule.ie...
Page 3
Installation and user manual Installation and user manual Installation and user manual installaton guide Installation and user manual Installation and user manual COMMISSIONING CHECKLIST AND WARRANTY CARD Product 7. COMMISSIONING CHECKLIST AND WARRANTY CARD 7. COMMISSIONING CHECKLIST AND WARRANTY CARD 7.
installaton guide Table of Contents Application Maintenance (yearly check) General General inspections Technical Specifications Cleaning Appliance layout Condensate pipe Wiring diagram Refrigerant circuit Storage and transport High limit safety cut-out Scope of supply Draining the cylinder Operating principle of the ventillation “SERVICE”...
1.1 GENERAL The appliance may only be used for DHW (Domestic Hot Water) heating . Using the boiler for any other purpose will be considered incorrect use . Joule accepts no liability for any damage resulting from such use . The appliance is not suitable for commercial or industrial applications .
installaton guide select your system 1.2 TECHNICAL SPECIFICATIONS Heating output – in accordance with EN255-3, air tempera- Unit 210L 260L 300L ture 20°C, heating water from 15°C to 45°C. Output 1,7* 1,7* 1,7* Total heating output (including electric booster heater) 3,7* 3,7* 3,7* 4,3* 4,3* 4,3* Standby energy consumption kW/day 0,74* 0,74* 0,74* Heating output –...
installaton guide 1.4 WIRING DIAGRAM WIRING DIAGRAM [1] NTC temperature sensor for air inlet This ballon and component is added in this picture, not in EPS [2] NTC temperature sensor [3] NTC temperature sensor in water inlet NTC temperature sensor for air inlet [4] Power cable This ballon and component is added in this picture, not in EPS [5] High Pressure Switch NTC temperature sensor [6] Electrical capacitor for compressor...
1.6 SCOPE OF SUPPLY This device is not intended for use by persons (including children) with physical, sensory or mental disability, of by persons with lack experience or knowledge, unless they have received Joule HeatBank from a person in charge of their safety adequate supervision or preliminary instructions on how to use the device. Flamco VHW 260...
Page 11
installaton guide 1.6.1 ACCESSORIES Data plate The data plate is located on the rear side of the appliance. This table need to be determined . 1.6.1 ACCESSORIES Description Article number This table need to be determined. Safety valve 12450 Description Article number Safety valve 12450...
• The evaporator will likely become clogged . Not allowed • Make a ventilation connection with a dryer. • Install in dusty room. • Take air in which contains solvents and / or explosive substances. • Connect the VHW to an extractor fan wich drains oily and contami- nated air . • Install the VHW in a room where there is a change of frost. • Install the VHW on top of the boiler. • Install in an atmosphere which is chlorinated (e.g. a swimming pool) or fluorinated. • Install nearby sea areas or chemical plant • Dusty air intake. www.joule.ie...
installaton guide 1.9 Configuration Installation 1 • Placing without ducts in an unheated room (volume > 20m • Set ducts OFF (see paragraph 4.8.5) • Select fan speed 1 (see paragraph 4.8.4) Examples of unheated rooms: • Garage: use the engine heat from a parked car or from household appliciances (e.g. a washing machine). • Washroom: dehumidifying the room and use the energy of the washing machine and dryer . •...
. Room/inlet air Keep the inlet air free of contaminants . It must not contain any of the following substances: • corrosive substances (ammonia, sulphur, halogen products, chlo- rine, solvents) • fatty or explosive substances • aerosol concentrations No other air inlet systems may be connected to the fan . www.joule.ie...
installaton guide Safety of electrical appliances for domestic use and similar purposes The following requirements apply in accordance with EN 60335-1 in order to prevent hazards from occurring when using electrical appliances: “This appliance may be operated by children aged 8 or over and by people with full physical, sensory and mental capabilities who have the necessary training and experience to use this type of appliance.
Page 16
Do not tilt the appliance on his feet more than 20°. • Assure correct positioning of all temperature sensors, see figure 2 and 3 . To ensure that the system operates faultlessly and the condensate drains correctly, the appliance must be aligned vertically . The appli- ance must tilt 1°, into the direction of the condensate drain. NOTICE Possible damage to external casing! • Do not tilt the appliance on his feet more than 20°. Fig. 3 www.joule.ie...
Installation and user manual Installation and user manual installaton guide 3.2 CONNECTING THE CONDENSATE HOSE Damage to the appliance! Connect the condensate hose to the con- CONNECTING THE CONDENSATE HOSE CONNECTING THE CONDENSATE HOSE densate drain before installing the part . •...
. Check the guideline 98/83/EG for the minimal requirements about potable water. Check the guideline 98/83/EG for the minimal requirements about po- table water . Note: In regions with more corrosive water, safety measures (filter, etc.) must be taken. The first inspection must always take place 6 months after installation. Note In regions with more corrosive water, safety measures (filter, etc.) must be taken. The first inspection must always take place 6 months after installation . www.joule.ie...
“+” or “-“ button to set the desired value. Pres the “ OK” button setting is confirmed. If the setting is not confirmed within 10 seconds, to confirm the setting. The set value flashes unit the setting is confirmed. If the the previously set value is retained . Once the temperature has been setting is not confirmed within 10 seconds, the previously set value is retained. set, the display indicates the water temperature in the cylinder . Once the temperature has been set, the display indicates the water temperature in the cylinder. www.joule.ie...
installaton guide 4.5 MAIN MENU Calling up the main menu: MAIN MENU MAIN MENU Press and hold the “Menu button for max . 3 seconds . Once you have Calling up the main menu: called up the main menu, you can select the following menus/sub- Calling up the main menu: menus: Press and hold the “Menu button for max. 3 seconds. Once you have called Press and hold the “Menu button for max.
• “Combi” operating mode Frost protection The electric booster heater starts up when the water temperature in the cylinder falls to 5 °C and switches off again when the temperature reaches www.joule.ie 8 °C. “MODE” SUBMENU - HEATING MODE...
installaton guide 4.7.1 ELECTRICAL HEATING MODE 4.7.1 ELECTRICAL HEATING MODE In this operating mode, the electric booster heater is the only heat In this operating mode, the electric booster heater is the only heat appliance appliance used. The water temperature can be set to between 30 °C used. The water temperature can be set to between 30 °C and 70 °C. and 70 °C. 4.7.1 ELECTRICAL HEATING MODE In this operating mode, the electric booster heater is the only heat appliance used.
The heat pump only goes into operation during the operating times set The heat pump only goes into operation during the operating times set at the factory. These cannot be changed: Days 1 - 5: [00:00 • “P1” operating time at the factory. These cannot be changed: Days 1 - 5: [00:00 • 06:00] set at the factory. These cannot be changed: Days 1 - 5: [00:00 • 06:00] and [16:00 • 19:00] Days 6 - 7: [02:00 • 08:00] and [16:00 • 19:00] Days 6 - 7: [02:00 • 08:00] 06:00] and [16:00 • 19:00] Days 6 - 7: [02:00 • 08:00] The heat pump only goes into operation during the operating times set at the factory. These cannot be changed: Days 1 - 5: [00:00 • 06:00] and [16:00 • 19:00] Days 6 - 7: [02:00 • 08:00] www.joule.ie...
Page 25
installaton guide “P2” and “P3” operating times “P2” and “P3” operating times The heat pump runs according to the operating times set by the user . The heat pump runs according to the operating times set by the user. “P2” and “P3” operating times “P2”...
. • Press “OK”. The current Legionella program is cancelled. Cancelling the “Leg” function. This only ends the current program; the weekly repetition is still active. • Call up the “Leg” function and press “OK”. “man” flashes on the display . • Press “+” until the display shows “LstP”. • Press “OK”. The current Legionella program is cancelled. This only ends the current program; the weekly repetition is still active. www.joule.ie...
installaton guide Installation and user manual 4.8.4 « FAN » - FANSPEED The fan can be used at two speeds 4.8.4 « FAN » - FANSPEED 4.8.4 « FAN » - FANSPEED Switching on the « FAN » function The fan can be used at two speeds The fan can be used at two speeds •...
4.10 DEFAULT SETTINGS After setting the temperature units and the time, the appliance adopts the default settings . • Heating mode: “Combi” After setting the temperature units and the time, the appliance adopts the • Operating mode: “Manual” default settings. • Heating mode: “Combi” • Selected temperature: 50 °C • Operating mode: “Manual” • Selected temperature: 50 °C • Heating mode: “Combi” • Operating mode: “Manual” • Selected temperature: 50 °C www.joule.ie...
installaton guide 4.11 FAULTS DISPLAY Installation, service and maintenance may only be carried out by a certified contractor. The following table lists the fault codes and their remedies . Display Description Remedy Fault in the temperature sensor at the top of the cylinder Notify certified contractor Notify certified contractor Temperature sensor for air inlet not working Notify certified contractor Temperature in cylinder > 80 °C If the problem persists after pressing “OK”,...
Page 30
1 . Reset button 2. Temperature setting of the high limit safety cut-off Temperature control unit After resetting, ensure that the temperature controller is in the position 1. Reset button shown in figure. 2. Temperature setting of the high limit safety cut-off After resetting, ensure that the temperature controller is in the position shown in figure. DRAINING THE CYLINDER www.joule.ie CAUTION: Risk of scalding! Check the appliance’s DHW temperature before opening the safety valve. Wait until the water temperature has dropped enough to prevent scalding and other damage!
Page 31
installaton guide 5.6 DRAINING THE CYLINDER CAUTION Risk of scalding! Check the appliance’s DHW temperature before opening the safety valve . Wait until the water temperature has dropped enough to prevent scalding and other damage! • Isolate the appliance from the power supply. • Close the water shut-off valve at the cold water inlet and open one DHW tap . • Open the drain tap.
Page 32
Packaging Where packaging is concerned, we participate in the relevant local recycling systems in order to ensure optimum Environmental protection is one of the fundamental company poli- recycling. All of our packaging materials are environmentally friendly and can be reused. cies of the Joule Group. Product quality, efficiency and environmental protection are equally important objectives for us. We comply with all Identifying plastics environmental protection laws and regulations . In order to protect the environment, we use the latest technologies and the best materials Used appliances contain materials that can be reused.
Need help?
Do you have a question about the HEATBANK and is the answer not in the manual?
Questions and answers