1.9 Configuration

Installation 1
Placing without ducts in an unheated room (volume > 20m
Set ducts OFF (see paragraph 4.8.5)
Select fan speed 1 (see paragraph 4.8.4)
Examples of unheated rooms:
Garage: use the engine heat from a parked car or from household
appliciances (e.g. a washing machine).
Washroom: dehumidifying the room and use the energy of the
washing machine and dryer .
Basement: recovering the energy that was released by the floor
and the walls .
Installation 2
Placing in a heated or unheated room, with ducts.
Set ducts ON (see paragraph 4.8.5)
Select fan speed 1 or 2 (see paragraph 4.8.4)
Recommendations:
Don't exceed the maximum length of the ducts (see paragraph 3.3).
Place grates before the air supply and air drain in order to prevent
damage to the VHW due to non-air elements which are eventual
drawn . Notice: manual blocking of the grates is not allowed.