Parameter
Name
No.
Un-13 Amount of PG
Speed Feedback
Amount of PG
Un-14
Speed Compen.
Un-15 PID Control Input
PID Control
Un-16
Output 1
PID Control
Un-17
Output 2
Un-18 Fault Message 1
Un-19 Fault Message 2
Un-20 Fault Message 3
Un-21 Fault Message 4
The Parameter
Of Time Period
Un-22
Between Last
Fault And The
Nearest Fault.
Frequency
Un-23
Command While
Fault Occurred
Output Freq.
Un-24
While Fault Occurred
Output Current
Un-25
While Fault Occurred
Un-26 Output Voltage
While Fault Occurred
DC Voltage
While
Un-27
Fault Occurred
I/P Terminal
Un-28
Status While
Fault Occurred
O/P Terminal
Un-29
Status While
Fault Occurred
Time Elapsed
Un-30
After Power-On
Time Elapsed
Un-31
After Run
EPROM S/W
Un-32
Version
Feedback
Un-33
Motor Speed
LCD display
(English)
Un-13= 100.0%
PG Feedback.
Un-14= 100.0%
PG Compen.
Un-15= 100%
PID Input
Un-16= 100%
PID Output1
Un-17= 00%
PID Output2
Overcurrent
Message1
Overcurrent
Message2
Overheat
Message3
Overtorque
Message4
Un-22= 2400Hr
Last Fault Run Time
Un-23= 60.00Hz
Last Fault Freq.Cmd. 0.01Hz
Un-24= 60.00Hz
0.01Hz
Last Fault O/P Freq.
Un-25= 12.5A
Last Fault O/P I
Un-26= 220.0V
Last Fault O/P V
Un-27= 310.0V
Last Fault O/P V
Un-28= 00000000
Last Fault I/P Term.
Un-29= 00000000
Last Fault O/P Term.
Un-31= 00002Hr
P Elapsed Time
Un-31= 00002Hr
R Elapsed Time
Un-32= 00001
Soft Number
Un-33= 00000rpm
Motor Speed
Unit
Description
0.1% 100.0%=MAX. output
frequency
0.1% 100.0%=MAX. output freq.
0.1% 100.0%=MAX. output freq.
0.1% 100.0%=MAX. output freq.
0.1% 100.0%=MAX. output freq.
Fault message occurred now
Fault message occurred
last time
Fault message occurred
last two time
Fault message occurred
last three time
The value of 'Run Elapse
Time' parameter will be
1Hr
cleared after fault has been
cleared.
0.1A
0.1V
0.1V
Same as Un-11,
display terminal status
Same as Un-12,
display terminal status
Display total time elapsed
1Hr
after power ON
Display total time elapsed
1Hr
after pressing RUN
-Manufacturing use-
Display motor speed while PG
1rpm
feedback is set.
101
Multi-function
Analog Output Level
10V/MAX. Output
Frequency
10V/MAX. Output
Frequency
10V/Max. output
frequency
10V/Max. output
frequency
10V/Max. output
frequency
10V/MAX. Motor
Speed