Dometic TEC60 Operating Manual page 27

Hide thumbs Also See for TEC60:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 8
TEC60, TEC60LPG
Fault
Cause
The generator
Too much oil in the engine.
tends to go off.
Load is over 6,2 kW.
Only TEC60:
Carburettor is not receiving any petrol.
Air intake is blocked.
Inverter is damaged.
Electromagnet (inverter) is blocked.
Air filter is dirty.
The generator is
Inverter is damaged.
running but does
RPM too low.
not supply any volt-
age.
The generator
The stepper motor is faulty or the cable is
starts up very fast
disconnected.
and then the
"GENERATOR
ALERT" message
appears.
The generated
Inverter is damaged.
voltage is unstable.
EN
Troubleshooting
Remedy
➤ Drain the oil.
➤ Switch off the consumers.
➤ Clean the carburettor.
➤ Check the air filter (see chapter
"Servicing the air filter" on
page 24).
➤ Contact an authorised workshop.
➤ Check the output wiring connec-
tion
➤ Contact an authorised workshop.
➤ Contact an authorised workshop.
➤ Contact an authorised workshop.
27

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tec60lpg91029002309102900229

Table of Contents