iComfort
Thermostat with a Non-
Communicating Outdoor Unit
®
icCmforti
Thermostat
®
iComfort
-Enabled Indoor Furnace
Non-Communicating Outdoor Air Conditioner
icomfort
ENABLED
FURNACE
OPTIONAL
DISCHARGE
AIR SENSOR
iComfort®
THERMOSTAT
CLIP ON-BOARD LINK
W915 (Y1 TO Y2) FOR
TWO-STAGE OPERATION
Outdoor Unit
®
-
OPTIONAL
OUTDOOR
AIR SENSOR
NON-COMMUNICATING
OUTDOOR AIR
CONDITIONING UNIT -
1 OR 2 STAGE
Indoor Unit
Controller
Single wire to
terminal C
Unused wires
Communicating systems using the IComfort
stat wires between the thermostat and the furnace/air handler control and four
wires between the outdoor unit and the furnace/air handler control. When a
thermostat cable with more than four wires is used, the extra wires must be
properly connected to avoid electrical noise. The wires must not be left discon
nected.
Use wire nuts to bundle the four unused wires at each end of the cable. A
single wire should then be connected to the indoor unit end of the wire bundle
and attached to the "C" terminals as shown above.
iComfort
iComfortt-ENABLED Outdoor Unit
®
iComfort
Thermostat
®
iComfort
-Enabled Indoor Furnace
iComfortt-Enabled Outdoor Air Conditioner or Heat Pump
OPTIONAL
DISCHARGE
AIR SENSOR
OPTIONAL
OUTDOOR
AIR SENSOR
iComfort®
THERMOSTAT
Single wire to
terminal C
Unused wires
®
thermostat require four thermo
FIGURE 56
Page 39
®
Thermostat with an
®
icomfort
-
ENABLED
FURNACE
®
iComfort
OUTDOOR AIR CONDITIONING
OR HEAT PUMP UNIT
iComfort®
THERMOSTAT
- ENABLED