Lennox EL296DFV Installation Instructions Manual page 24

Elite series gas furnace downflow air discharge
Hide thumbs Also See for EL296DFV:
Table of Contents

Advertisement

Maximum Allowable Exhaust Vent Pipe Length (in ft.) Without Insulation In Unconditioned Space For
Winter Design
1
Temperatures
°F (°C)
32 to 21
(0 to -6)
20 to 1
(-7 to -17)
0 to -20
(-18 to -29)
1
Refer to 99% Minimum Design Temperature table provided in the current edition of the ASHRAE Fundamentals Handbook.
2
Poly-Propylene vent pipe (PP) by Duravent and Centrotherm.
NOTE - Concentric terminations are the equivalent of 5' and should be considered when measuring pipe length.
NOTE - Maximum uninsulated vent lengths listed may include the termination(vent pipe exterior to the structure) and cannot exceed 5 linear feet or the
maximum allowable intake or exhaust vent length listed in table 7 or 9 which ever is less.
NOTE - If insulation is required in an unconditioned space, it must be located on the pipe closest to the furnace. See figure32.
Winter Design Temperatures Two - Stage High Efficiency Furnace
Vent Pipe
Diameter
045
PVC
2 in.
21
2-1/2 in.
16
3 in.
12
2 in
11
2-1/2 in.
7
3 in.
N/A
2 in.
6
2-1/2 in.
N/A
3 in.
N/A
Conditioned
Space
TABLE 8
Unit Input Size
070
2
2
PP
PVC
PP
18
33
30
N/A
26
N/A
12
21
21
9
19
17
N/A
14
N/A
N/A
9
9
4
12
10
N/A
7
N/A
N/A
N/A
N/A
Conditioned
Space
Pipe Insulation
Unconditioned
Space
FIGURE 32
Page 24
090
2
PVC
PP
PVC
46
42
30
37
N/A
36
30
30
29
28
25
27
21
N/A
20
16
16
14
19
16
18
13
N/A
12
8
8
7
Exhaust
Pipe
Intake
Pipe
110
2
PP
30
N/A
29
24
N/A
14
15
N/A
7