Electrical Adjustments
Group/
Item Name
Item
2 VOLTAGE_LEVEL
24 DIMMER_LEVEL_HIGH
Group
Projector Warning Log
220
0 Warning Log_1
.. ..
49 Warning Log_50
50 Warning Log Reset
Group
FAN control
250
0 FAN1 MIN ADJUST (DAC)
1 FAN1 MAX ADJUST (DAC)
2 FAN2 MIN ADJUST (DAC)
 FAN2 MAX ADJUST (DAC)
4 FAN MIN ADJUST (DAC)
5 FAN MAX ADJUST (DAC)
Group
Filter detection setting
251
0 Filter Warning Calibration
1 Filter Warning Offset Optio-0
2 Filter Warning Offset Optio-1
 Filter Warning Offset Optio-2
4 Filter Warning Offset Optio-
5 Filter Warning Offset Optio-4
6 Filter Warning Offset Optio-5
7 Filter Warning Offset Optio-6
8 Filter Warning Offset Optio-7
9 Not Used
10 Not Used
11 Not Used
12 Not Used
1 Filter Warning Times
14 Fan-Add Filter Level 1
15 Fan-Add Filer Level 2
16 Filter Warning Calibration Range
17 Filter Warning Calibration Time
18 Filter Warning Calibration Error Log
19 Filter Warning High Land Calibration Error Log
20 Fliter Warning Calibration Temp
21 Filter Warning Inclination Rpm (to 26˚C)
22 Filter Warning Inclination Rpm (over 26˚C)
2 Filter Warning Add Offset Rpm
Group
Fan option
252
0 Fan Max SWITCH
1 SAFETY SWITCH
2 FAN MANUAL SWITCH
 FAN1 MANUAL VOLTAGE
4 FAN2 MANUAL VOLTAGE
5 FAN MANUAL VOLTAGE
6 FAN4 MANUAL VOLTAGE
7 FAN5 MANUAL VOLTAGE
8 FAN6-8 MANUAL DUTY
9 All Fan MaxMin Control
10 Press Data
Group
Fan tem error Setting (Memorized)
253
0 Temp A Warning (High)
1 Temp B Warning (High)
2 Temp C Warning (High)
 Temp B-A Warning (High)
4 Temp C-A Warning (High)
5 Temp A Warning (Normal)
6 Temp B Warning (Normal)
Function
Lamp Voltage
Dimmer level High
DAC Output for Fan
Adjust the tolerance of DAC and Fan
Volage.
* Lamp mode is forced Eco
0: Normal, 1: Max (1.5V)
For test purpose
0: Auto, 1: Manual
Fan Voltage (unit : 0.1V)
Effective only when Fan Maual
switch is 1
Temp. A to judge the Temp Error at
High (Room)
Temp. B to judge the Temp Error at
High (Panel)
Temp. C to judge the Temp Error at
High (Lamp)
Temp. B-A to judge the Temp Error at
High (Clogging Det.)
Temp. C-A to judge the Temp Error at
High (Clogging Det.)
Temp. A to judge the Temp Error at
Normal (Room)
Temp. B to judge the Temp Error at
Normal (Panel)
Initial
-
15
-
-
-
-
7
224
1
224
1
224
0
171
2686
456
419
4728
5221
5607
5899

1000
2000
1
2
255
255
260
60
80
-
0
0
0
100
100
100
100
100
-
0
Normal
Ceiling
46
46
62
62
62
62
100
100
100
100
46
46
60
61
-42-
range
Note
Unit: 8bit(Raw Data) * Read only
0 - 15
0-2767
..
0-2767
0-10
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0-1
0000-9999
0000-9999
0000-9999
0000-9999
0000-9999
0000-9999
0000-9999
0000-9999
0-10
0000-9999
0000-9999
0-10
0-10
0-255
0-255
-
0000-9999
0000-9999
-
0 - 1
0 - 6
0 - 1
0 - 145
0 - 145
0 - 145
0-255
0-255
0-511
0 - 6
0-100
0-100
0-100
0-100
0-100
0-100