RCS TBZ48 Operation Manual
Hide thumbs Also See for TBZ48:

Advertisement

Heating/Cooling
Mode Selection
Fan Mode
Selection
DCN: 141-02071-01
Operation Guide
Model TBZ48
Z-Wave Thermostat

Main Thermostat Screen

Backlite Display
OFF
MODE
AUTO
FAN
Setpoints
Room Temperature
72H 80C
72H 80C
72H 80C
72H 80C
74
RUN
Compartment
Temperature
Setting
Warmer
Cooler
Battery
Page 1

Advertisement

Table of Contents
loading

Summary of Contents for RCS TBZ48

  • Page 1: Main Thermostat Screen

    Operation Guide Model TBZ48 Z-Wave Thermostat Main Thermostat Screen Setpoints Backlite Display Room Temperature Temperature Heating/Cooling Setting Mode Selection 72H 80C 72H 80C 72H 80C 72H 80C Warmer MODE Fan Mode AUTO Cooler Selection Battery Compartment DCN: 141-02071-01 Page 1...
  • Page 2: Setting The Heating Or Cooling Temperature Setpoint

    Setting the heating or cooling temperature setpoint 72H 80C 72H 80C 72H 80C 72H 80C MODE Press a button to go to the setpoint AUTO change screen Press the up or down arrow buttons to Setpoint change screen set the desired temperature setpoint Setpoint being changed...
  • Page 3: Setting The System Mode: Off, Heat, Cool, Auto

    Setting the System Mode: Off, Heat, Cool, Auto Press Mode button to change system 72H 80C 72H 80C 72H 80C 72H 80C mode MODE Auto System Modes Off: System is off. No heating or cooling will come on. If system was on, it will •...
  • Page 4: Setting Fan Mode

    Setting Fan Mode 72H 80C 72H 80C 72H 80C 72H 80C MODE Auto Press the Fan button to change the Fan mode Auto: Fan automatically operated by the HVAC system. • On: Manual Fan mode. Fan stays on until mode is changed back to Auto. •...
  • Page 5: Menu Selection

    Menu Selection 72H 80C 72H 80C 72H 80C 72H 80C MODE Auto Press and hold Fan button to go to the main menu screen SETUP SETUP SETUP SETUP Press SELECT to MODE Select go to the menu Use the item screen UP/DOWN Done buttons to select...
  • Page 6: System Menu Items

    C Away Away setpoints are used when the thermostat is set to the setback or away mode. H Away Away setpoints are used when the thermostat is set to the setback or away mode. System Menu Items Systype Select the system type, HP for HeatPump, S for Standard (Gas/Elec) CO Select the ChangeOver type (HP systems only), changeover with Heat or Cool Fantype Select Fantype (Gas/Elec only), Gas or Electric ZWave Install...
  • Page 7: Thermostat Operation

    Thermostat Operation Minimum Run Time (MRT) The thermostat has a Minimum Run Time after the start of any heating or cooling call. This minimum run time assures even heating and cooling cycles. The MRT delay will keep the system on even if reaches setpoint or you change the setpoint to a temperature that would satisfy the call, until the MRT expires.
  • Page 8: Z-Wave® Installation

    Z-Wave controllers from various manufacturers support the Z-Wave process of adding or removing a device from a network. The TBZ48 is a Z-Wave Slave and a Z-Wave controller is required as the primary controller to setup and maintain the network.
  • Page 9: Setback Mode Operation

    Exclusion: Removing the TBZ48 from a Network Set your primary controller to Remove mode, to remove the TBZ48 as a node on your network (see your controller’s user manual for detailed instructions). Press the FAN button and hold until the screen changes to the SETUP screen.
  • Page 10 FCC/IC INFORMATION TO USER This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation.