Programming
Operating Instructions 550-867 - 00.0 - 11/2016
Information
The thread tension is monitored for every stitch during the docu-
mented seam section. As soon as the thread tension falls outside
the tolerance range, the sewing process stops, and an error
message is displayed.
If the seam record set is linked to a teach-in file, the data stored
in the teach-in file will overwrite the manually entered data.
Linking a thread tension teach-in file
A thread tension teach-in file is used to store all important data
necessary to set the tolerance for the electronically regulated
thread tension (for ETT only). It is possible to link such a teach-in
file to every seam section.
A different teach-in file can be linked to each documented/free
seam section.
To link a teach-in file to a seam section:
1.
Open the Seam record set display ( p. 102).
2.
Tap the Thread.Tens. Teach-In input field.
 The directory holding the teach-in files that are stored on the
control panel opens.
3.
Select the desired teach-in file.
4.
Confirm with OK.
To display the stored values:
1.
Open the Seam record set display ( p. 102).
2.
Tap the Edit button at Thread.Tens. Teach-In.
 The values stored in the teach-in file are displayed.