B. Parameter of error code
This is the detail of error code.
Example of Error code
01. 01 05 04 04
00 00 00 00
C. Time of error code
This is the laser time when an error occurred.
Example of Error code
01. 01 05 04 04
00 00 00 00

To Clear the Laser Hour

Press the [
DISPLAY] button on the remote commander and then
press the [CLEAR] button on the remote commander. The data for
both CD and DVD data are reset.
Emg. History Check
Laser Hours
CD
DVD
01. 01 05 04 04
00 00 00 00
02. 02 02 01 01
00 00 00 00
[Next]Next page [Prev]Prev page
[0]Return to Top Menu
To Clear the Emergency History
Press the [DVD TOP MENU] button on the remote commander
and then press the [CLEAR] button on the remote commander. The
error code for all emergency history would be reset.
Emg. History Check
Laser Hours
CD
DVD
01. 00 00 00 00
00 00 00 00
02. 00 00 00 00
00 00 00 00
[Next]Next page [Prev]Prev page
[0]Return to Top Menu
00 92 46 00
00 00 23 45
00 92 46 00
00 00 23 45
0h
0min
0h
0min
00 92 46 00
00 00 23 45
00 A9 4B 00
00 00 23 45
999h
59min
999h
59min
00 00 00 00
00 00 00 00
00 00 00 00
00 00 00 00

To Execute the Initialize Setup Data

Procedure:
1. Press the [DVD MENU] button on the remote commander and
then press the [CLEAR] button on the remote commander. The
following screen appears on the on-screen display.
Emg. History Check
Laser Hours
CD
DVD
Initialize setup data...
[Next]Next page [Prev]Prev page
[0]Return to Top Menu
2. The screen after a while returns to former display.
To Return to the Top Menu of Remocon Diagnosis
Menu
Press the [0] button on the remote commander.
3-5. Checking Version Information
To check the version information, please follow the following pro-
cedure.
Procedure:
1. From the top menu of Remocon Diagnosis Menu, select "4.
Version Information" by pressing the [4] button on the remote
commander. The following screen appears on the on-screen
display.
Version information
Firm(Main): Ver. X.XXXX
Firm(Sub): XX.XX
RISC: XXXXXX
8032: XXXXXX
Audio DSP: XX.XX.XX.XX
Servo DSP: XX.XX.XX.XX
[0]Return to Top Menu
2. To return to the top menu of Remocon Diagnosis Menu, press
the [0] on the remote commander.
HCD-F200/F500
999h
59min
999h
59min
27