Premier WP-5 Installation, Operation And Maintenance Manual

Premier WP-5 Installation, Operation And Maintenance Manual

Watts premier

Advertisement

INSTALLATION, OPERATION AND MAINTENANCE MANUAL
Warning
Please read carefully before proceeding with installation. Your failure to follow any attached instructions
or operating parameters may lead to the products failure and possible damage to property.
Save manual for future reference
MODEL
WP-5 WP5-50 KP-5 RO-5M
performance data sheet.
Refer to enclosed warranty for operating parameters to ensure proper use with your water supply.
Watts Premier
8716 W Ludlow Drive, Suite 1
Peoria, AZ 85381
Phone: 800-752-5582
www.premierH2o.com
Fax: 623-866-5666
Manual: 199349
Manual Date: 07/21/2016
Page 1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the WP-5 and is the answer not in the manual?

Questions and answers

Summary of Contents for Premier WP-5

  • Page 1 Save manual for future reference MODEL WP-5 WP5-50 KP-5 RO-5M performance data sheet. Refer to enclosed warranty for operating parameters to ensure proper use with your water supply.
  • Page 2 Giardia. There may also be some local water issues in your area such as high levels of lead and copper. This Premier water treatment system has been designed and tested to provide you with high quality water for years to come.
  • Page 3: Table Of Contents

    Table of Contents Operational Parameters ........................4 Contents of Reverse Osmosis System .................... 4 Installation & Startup ....................4 Plumbing diagram and parts list ...................... 5 .................. 6 ..............6 ......................7 ....................... 8 Reverse Osmosis Module Mounting....................8 ........................9 Drain Saddle Tube Connection......................
  • Page 4: Operational Parameters

    Copper Tube: Reverse Osmosis water should not be run through copper tube as the purity of the Contents of the Reverse Osmosis (RO) System 1 Manual If any of the items are missing please contact Premier prior to installing. INSTALLATION & STARTUP Tools Recommended For Installation...
  • Page 5: Plumbing Diagram And Parts List

    Item Part # Description 101009 Carbon Block-10 Inch-5M COLD WATER 104017 Sediment Filter-10 Inch-5M ANGLE-STOP 560014 RO Membrane 25GPD (@ WP-5) (SUPPLY) 3 ALT 560018 RO Membrane 50GPD (@ WP5-50) 113018 Filter Bowl 113035 Membrane Vessel 113041 O-Ring Filter Bowl...
  • Page 6 (If you are already using it for a sprayer or soap dispenser, see step 1) Porcelain sinks are extremely hard and can crack or chip easily. Use extreme caution when drilling. Premier accepts no responsibility for damage resulting from the installation of faucet. Diamond tip bit recommended.
  • Page 7 PremierH2o Standard Faucet Installation Parts List Faucet Escutcheon Plate Full Circle Rubber Gasket Plastic Tube Insert Step 5 is seated. Step 6 Page 7...
  • Page 8: Reverse Osmosis Module Mounting

    Adapt-a-Valve Installation Caution: Water supply line to the system must be from the cold water supply line only. Hot water will severely damage your system. Verify contents prior to installation: Black Collet White Washer White Washer Cold (With Brass Fittings) (Without Brass Supply Supply...
  • Page 9: Drain Saddle Tube Connection

    Installation of the drain saddle near a garbage disposal may cause the drain line to plug. If no other installation of drain line is available, Premier offers drain line installation kit (part number 164020) that can be used with garbage disposals.
  • Page 10: Green Tube Connection

    Green Tube Connection Green Tube Step 16 all the way to the tube stop. Tank Elbow Installation Step 17 Note: Do not let the tape cover the opening. Step 18 wrench. Do not over tighten as plastic could crack. Connect Blue Tube from “TANK” Port on RO Module to the Tank Step 19 and cut it to desired length.
  • Page 11 Final Polishing Filter Installation Step 22 Step 23 Step 24 1/4” 3/8” Note: Do not overtighten these connectors as it may damage them Step 25 Note: A connection to a refrigerator / ice maker may be tee’d into this blue tube and should Page 11...
  • Page 12: Start Up Instructions

    Start up Instructions Turn on the incoming cold water at the angle stop valve and the Step 1 Note: If you have connected your RO system to a refrigerator / ice maker, make sure the ice maker is have an in-line valve installed before the ice maker so it can easily be closed to prevent water Step 2 Step 3 temperature and water pressure.
  • Page 13: Maintenance & Troubleshooting Six Month Maintenance

    6 Month System Maintenance Items needed: Note: Step 1 Turn off the incoming water supply to the RO at the feed water valve. Step 2 Note: Water may be saved in a container for drinking or to rinse system parts. Step 3 Step 4 housing...
  • Page 14: Annual Maintenance

    Annual Maintenance • • • • NOTICE: Sanitizing of unit is recommended. Step 2: NOTICE: If not sanitizing the system, skip to step 9 Replace empty membrane housing onto unit. DANGER continue rinsing eye. Call a poison control center or doctor for treatment advice. Step 5: Let the system sit idle for 1 minute Step 6:...
  • Page 15: Membrane Replacement

    TDS reduction falls below 75% NOTE: A water sample may be sent to Premier for a free diagnosis of your membranes performance. Send the samples to the address listed on the cover of this manual attention “Water Samples”.
  • Page 16: Check Air Pressure In The Tank

    Check Air Pressure in the Tank Important: Check air pressure only when tank is empty of water! Check air pressure in the storage tank when you notice a decrease in available water from the RO system. Air can be added with a bicycle pump using the schrader valve that is located on the lower side of the tank behind the blue plastic cap.
  • Page 17: Troubleshooting

    TROUBLE SHOOTING Problem Cause Solution Premier sells a booster pump if home water pressure is valve is all the way open. times. necessary. Drain tube clogged Caused from dishwasher or garbage disposal. air through the line will not always remove the clog.
  • Page 18: Performance Data Sheet

    Performance Data Sheet WP-5 Watts Premier 8716 W Ludlow Drive Suite #1 Peoria, AZ 85381 (480) 675-7995 4. pH 2 to 11 Description Change time Frame be used on water supplies containing a detectable free chlorine residual at the system inlet or on water supplies that have been demonstrated to...
  • Page 19: Performance Data Sheet

    Performance Data Sheet WP5-50 Watts Premier 8716 W Ludlow Drive Suite #1 Peoria, AZ 85381 (480) 675-7995 1. System to be used with municipal or well water sources treated and tested on regular basis to insure bacteriological safe quality. Do not use 5.
  • Page 20 Other water treatment chemicals such as ozone and potassium permanganate will also change trivalent system. This Premier reverse osmosis system is designed to remove up to 98% of pentavalent installation. The RO component of this Premier reverse osmosis system must be maintained www.premierh2o.com.
  • Page 21: Service Record

    Service Record Date of Purchase:__________ Date of Install:___________ Installed by:__________________ 2 nd stage 3rd stage Final Filter 1st stage Date Carbon Carbon Carbon Membrane Sediment (6 months) (6 months) (1 year) (2-5 years) (6 months) NOTES: Page 21...
  • Page 22: Limited Warranty

    If any part of your Reverse Osmosis System is defective in workmanship (excluding replaceable filters and membranes), return unit after obtaining a return authorization (see below), less tank, within 1 year of original retail purchase, Watts Premier will repair or, at Watts Premier’s option, replace the system at no charge.

This manual is also suitable for:

Wp5-50Kp-5Ro-5mWp-4v

Table of Contents