3. Installing the Mounting Plate
C
4. Installing the Magnet Sensor Set
Right-handed
5. Connecting the cable
B
SET
REG
C
G2
Left-handed
3/4˝(20mm)
REG
REG
SET

1. Detach the Interior Mounting Plate from
the interior unit.
2. Fasten the interior mounting plate with
three TH+M4x40 (G2) 90% of the way.
3. Align the Exterior Unit with the Interior
Mounting Plate and then tighten the
screws.
4. Cover the rubber pad on the Interior
Mounting plate.
CAUTION: Do not over-tighten, and check
the movement of dead bolt by the mechani-
cal key.
Install the door sensor.
It should be installed in right way of the door.
The user has an option not to use/install the
magnet sensor. In order to disable, the user
shall let the door sensor sense the magnet for
only once in installation for setting of right or left
handed use.
CAUTION: The gap of the door sensor between
the door side and the door-frame should be
within 3/4"(20mm). If the gap is to wide, pull out
the door sensor to adjust the gap enough to
detect.
1. Connect the cable from the exterior unit
to the interior unit.
2. After connecting the cable, push the
cable into the hole of the door.