Error code
Error message
!00002
Not available
!00003
Not implemented
!00004
Value out of range
2.3
Examples

SET commands

Command
:POWR1'CR'
%001 POWR 000001'CR'
Command
:BRIG 60'CR'
%001 BRIG 000060'CR'
Command
:CNTR R1'CR'
%001 CNTR 000061'CR'
Command
:CNTR R-2'CR'
%001 CNTR 000059'CR'
SET commands with target
Command
:TATB 1 3'CR'
%001 TATB 000001'CR'

GET commands

Command
:CNTR?'CR'
%001 CNTR 000059'CR'
Command
:BRIG ?N'CR'
%001 CNTR 000000'CR'
GET commands with target
Command
:TATB ? 3
%001 TATB 000001 'CR'
601–0381–00 F(L)35, FS35 IR, F85 21/10/2015
Description
Logic conflict prevents command being available. For example, contrast is not
available when the projector is searching for sources.
Command not available for this projector configuration. See relevant comments
section in ASCII commands for information.
Value is not within valid range.
Description
Set power on
Acknowledge power on
Description
Set brightness to 60
Acknowledge brightness
Description
Increase contrast
Acknowledge increase contrast
Description
Decrease contrast
Acknowledge decrease contrast
Description
Set aspect trigger behavior 16:10 to off
Acknowledge set aspect trigger behavior 16:10 to off
Description
Get current value contrast
Acknowledge get current value contrast
Description
Get minimum value brightness
Acknowledge get minimum value brightness
Description
Get aspect trigger behavior 16:10
Acknowledge get aspect trigger behavior 16:10