1. COMMUNICATION SETTINGS

Overview

Set up LAN Communication

Set up RS232 communication
1.1
Set up LAN Communication
General
The supported RS232 settings are as follows:
Parameter
Baud rate
Data bits
Parity
Stop bits
Flow control
General
The default settings of the projector when shipped are as follows:
Description
DHCP
IP address
Subnet mask
Default gateway
TCP/UDP port
Input IP settings on the projector
Before you connect the projector to your LAN make sure that the IP settings are set correctly, according to your LAN configuration.
IP settings can be changed using the projector On Screen Display (OSD) Settings menu.
Set up can be done automatically using DHCP (Dynamic Host Configuration Protocol). When DHCP is enabled, it may take up to a
minute for the projector to receive IP settings from the DHCP server. The IP address will be updated and shown in the OSD. If there
is no DHCP server in the network the projector will be assigned a "zero configuration" address, 169.254.0.0/16.
Alternatively, DHCP can be manually disabled and the user can manually input the projector IP address, Subnet mask and Gateway
in the LAN network menu of the OSD.
To renew an IP address, select "renew" in the OSD LAN settings menu.
Connect the projector and the host
As soon as the projector IP settings are set correctly, you can physically connect the selected host, for example a computer, and the
projector. This can be done in two ways:
use a crossover twisted pair (TP) cable directly from the computer to the projector
use two straight-through TP cables with a HUB or a switch between them
1.2
Set up RS232 communication
Connect to the projector
Connect the projector and host using a standard straight through serial cable (host : female, projector : male).
Pin 2 connects to Pin 2, Pin 3 connects to Pin 3, and Pin 5 connects to Pin 5.
601–0381–00 F(L)35, FS35 IR, F85 21/10/2015
Data
19200
8
None. There is no parity bit used to perform error checking.
1. One stop bit is used to define the end of a character.
None.
Value
On
0.0.0.0
0.0.0.0
0.0.0.0
1025
1. Communication settings
1

Advertisement

loading

This manual is also suitable for:

Fs35 irF85