JLG 3507 Operator's Manual page 109

Hide thumbs Also See for 3507:
Table of Contents

Advertisement

B. Element Change (as restriction indicator indicates)
1. Unlock air cleaner cover (4), turn counterclockwise and remove from air cleaner
canister (5).
2. Remove outer primary element (6) and inspect for damage. Damaged elements
should not be reused.
3. Thoroughly clean the interior of the air cleaner canister and vacuator valve.
4. Replace inner safety element (7) after every third primary element change. If
replacing the inner safety element at this time, carefully slide the element out
and replace with new element.
5. Slide the new primary element over the inner element making sure the sealing
edge is flush with the base of the air cleaner.
6. Position air cleaner cover in place, turn clockwise and lock into position.
7. Depress button on restriction indicator to reset.
Note: An inner safety element should never be washed or reused. Always install a
new element.
3121851
Section 6 - Lubrication and Maintenance
6-11

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

350835094007400940084013 ... Show all

Table of Contents