Accessible 5.25-inch drive
V
CAUTION!
If screws are too long, they may damage the drive.
Accessible drive
LTO2 HH Ultrium
LTO3 HH Ultrium
LTO4 HH Ultrium
DDS Gen 5
DDS Gen 6 (USB / SCSI)
RDX drive
*
These screws are included in the delivery of the drive.
Ê Push the new drive about halfway into the bay.
Ê Connect the data cable to the accessible drive (see the cabling plans in the
Appendix).
Ê Connect the power cable to the accessible drive (see the cabling plans in the
Appendix).
Ê Push the drive fully into the bay until the EasyClick rails lock in place.
Ê Attach the front cover or rack front cover and close the server (see chapter
"Completion" on page
46
123).
Options Guide
Accessible drives
Required screws
M3 x 3,5 mm *
M3 x 3,5 mm *
M3 x 4,5 mm
M3 x 4,5 mm
M3 x 4,5 mm
M3 x 4,5 mm
TX300 S5