Product Guide ineo 1051/1200
Power range
Rated voltage
Power sag
Impulse noise
Range of Power supply
voltage fluctuation
Frequency
Wave form
Tolerance
Installation requirements
Reliability
Precondition
Extreme storage
environment
Coverage range
Failure/JAM
Machine life
Europe: -14 to +10.6%
Continuing max 100ms: 10%
Within twice the peak value of Line voltage, pulse width 50 to 1000ns
3% or less, for voltage when machine under full-load compared to no-load
Sine wave, distortion less than 5%
±2.5Hz (for all destinations)
Machine must not be exposed to strong air ventilation or extreme direct
sun light.
Floor space must allow horizontal, stable machine installation
- Environmental conditions
Under a range of Q-zone and B-zone of section 2-3
- Condition of copying / printing paper for evaluation samples
Recommended paper for each destination and freshly unpacked
paper should be used.
- Machine condition
The machine installed and maintained properly.
- Specification value
The value in this specification is a reference value based on an in-
house examination
1.Print rate: 10% on average
2.Load factor: 41 on average
3.Media ratio:
Color /Fine quality paper: 47%
Coated paper: 30%
Color/Fine quality thick paper: 8%
Coated Thick paper: 15%
Extreme temperature for 24 hours:
Main body:
Toner:
max 50°C at 40%RH or less (without condensation)
0.5 – 95 %
Productivity declines when 30% or above.
MCBF
300k print
MCBJ
50k print
90 million (A4) or 7 years whichever is first