Installing the refrigerator
6.3
Making air inlet and outlet vents
I
NOTE
At high ambient temperatures, the refrigerator can only provide its
maximum cooling capacity if the optimum ventilation has been
provided.
➤ Make an air inlet vent and an air outlet vent in the outer wall with the
size of 410 mm x 249 mm. When doing so, observe the information, see
chapter "Preparing the installation" on page 17.
If the ventilation grille of the air inlet vent cannot be installed flush with the
floor of the niche, you need to install an inlet vent in the floor:
➤ Make an air inlet vent in the floor (fig. 3 4, page 3) behind the refrigerator
near the gas burner.
➤ Shield the end of the opening with a deflector to prevent sludge or dirt
from getting inside while driving (fig. 9, page 5).
If you have to use a roof vent instead of the air outlet vent:
➤ Cut out a section in the roof. Refer to the roof vent instruction manual for
the required dimensions. When doing so, observe the information, see
chapter "Preparing the installation" on page 17.
6.4
Installing the ventilation grille
No. in
fig. 0, page 5
1
2
3
4
➤ Ensure the installation frame is water resistant (fig. a, page 6).
➤ Insert the installation frame and screw it down tightly (fig. b, page 6).
➤ Fit the ventilation grille (fig. c, page 6).
➤ Insert the slider and lock the ventilation grille with it (fig. c, page 6).
20
Description
Installation frame
Ventilation grille
Winter cover
Slider
RML9330 – RML9435