Installing the refrigerator
 If the ventilation grille of the air inlet vent cannot be installed flush to the
ground, an additional inlet vent (fig. 3 4, page 3) must be provided in the
floor for releasing leaked gas.
 A distance of more than 40 mm between the refrigerator and rear wall
leads to poor performance and increases the power consumption of the
refrigerator. Reduce the space behind the refrigerator to create adequate
air inlet and outlet ventilation (fig. 5, page 4). Use a ventilation plate, for
example, to do this.
 If the minimum distance between the air inlet and outlet vents cannot be
met, a roof vent must be installed instead of the air outlet vent.
– The roof vent should be installed directly above the back of the
refrigerator as far as this is possible. Use an air duct (fig. 6 1, page 4)
if you need to install the roof vent offset, otherwise heat will accumu-
late there.
– The distance between the air inlet vent and the roof vent must be at
least 1350 mm (fig. 6, page 4).
– If a roof air conditioner is provided, the distance between the roof vent
(fig. 7 1, page 5) and the air outlet of the roof air conditioner
(fig. 7 2, page 5) must be at least 300 mm.
 The refrigerator must not be installed at the side of the air inlet and outlet
vents as this leads to poor performance and increases the power
consumption of the refrigerator.
 The air inlet and outlet vents must not be covered by vehicle parts (such
as an open door or by installing accessories such as bicycle racks) while
operating.
 Install a fan kit for distances of 25 mm – 45 mm between the rear wall of
the refrigerator and air outlet vent (see chapter "Accessories" on
page 16).
 Install the refrigerator so that it is protected from excessive heat, as this
leads to poor performance and increases the power consumption of the
refrigerator.
 The electrical installation must comply with national and local regulations.
European standards: EN 60335-1, EN 60335-2-24, EN 1648-1 and
EN 1648-2.
 The gas installation must comply with national and local regulations.
European standard: EN 1949.
 The refrigerator must be installed in a draught-proof location in
accordance with EN 1949, see chapter "Installing the refrigerator in a
draught-proof location" on page 19.