Wachendorff ur3274 User Manual page 12

Hide thumbs Also See for ur3274:
Table of Contents

Advertisement

Relay Q1 Output
Q2
Q1
SSR output
SSR
Digital Input
12
UR3274U - User manual
Capacity:
Q1: 8A, 250Vac,resistive loads,10
tions. 30/3A, 250Vac, cosφ=0.3, 10
operations.
Q2: 5A, 250Vac, resistive loads, 105
operations.
20/2A, 250Vac, cosφ=0.3, 10
rations.
SSR command output 12V/30mA
Digital input according to parameter
The use of digital input in this version is
possible only with TC sensors or 0...10V,
0/4...20mA and 0...40mV signals
opera-
5
5
ope-
5
DGT. i .

Advertisement

Table of Contents
loading