Omron V740-BA50C22A-US Operation Manual page 15

V740-series uhf rfid system reader/writer antenna
Table of Contents

Advertisement

Status Page
The Status page indicates the connected antennas,
software version and LAN configuration of the reader.
IMPORTANT: Check to see that at least one antenna
port is connected before performing any tag queries or
tag write operations.
1. Click the Status link in the navigation menu to
display the Status page.
2. Close the browser window if you are finished
using the browser-based interface.
Note: The status of 'Connected Antenna Ports' is
displayed as 'Connected' only for the antennas
connected to the V740 reader when it starts up.
V740 RFID READER/WRITER, ANTENNA
OPERATION MANUAL
Query Page
The Query page is mainly used to set up and run anti-
collision searches quickly and gives you immediate
feedback, which can be useful for verifying
performance when installation is complete and for
debugging.
At the bottom of the screen is the Query field in which
RQL search statements can be entered or selected
from the stock queries found in the drop-down list to
the right of the Query field. The RQL search statement
in the Query field specifies which tag protocols will be
read, which antenna ports are to be used, how long
the query is to be run, and other read operation
parameters. The query can be run once or
continuously.
Note: The selected settings DO NOT affect reader
performance associated with other applications.
The following stock queries are available from the
drop-down list:
Each mode provides the most suitable time out value
for the protocols and the number of tags to be read.
fewer than 10 EPC1 tags
fewer than 50 EPC1 tags
fewer than 100 EPC1 tags
Note: Only the modes that contain EPC1are
available on this type of V740 reader.
15 of 56