6.3 Running D-Link NetXtreme User
Diagnostics
Running in MS-DOS Command Prompt Mode
At the MS-DOS prompt, type b57udiag using the command options as shown in Table 1.
NOTE: In MS-DOS Command Prompt mode, you must include b57udiag at the beginning of
the command string each time you type a command.
Table 1: MS-DOS Command Prompt Mode Command Options
Command Options
b57udiag
b57udiag -c <num>
b57udiag -cmd
b57udiag -mba <value>
b57udiag -mbap <value>
b57udiag -mbas <value>
b57udiag -firm <file>
Description
Performs all of the tests on all of the D-Link NetXtreme
Gigabit Ethernet adapters in your system.
Specifies the adapter to test, or the adapter on which to
update the firmware or to view or change the settings for
available properties.
Changes to the Broadcom CLI mode.
Enables/disables Multi-Boot Agent (MBA) protocol.
1 = Enable
0 = Disable
Selects the specific MBA protocol.
0 = Preboot Execution Environment (PXE)
1 = Remote Program Load (RPL)
2 = Bootstrap Protocol (BOOTP)
Selects the MBA speed and duplex mode.
0 = Auto
1 = 10 Mbps speed, half-duplex operation
2 = 10 Mbps speed, full-duplex operation
3 = 100 Mbps speed, half-duplex operation
4 = 100 Mbps speed, full-duplex operation
6 = 1000 Mbps speed, full-duplex (fiber)
Updates the EEPROM of the selected adapter based on the
match between the existing image file name and the new
image <file name>.