5. DESCRIPTION OF THE LCD DISPLAYS

FIRST DISPLAY (kg)
The weight on the plate is shown in this display.
SECOND DISPLAY (€/kg €/100g)
The entered average price is shown in this display.
THIRD DISPLAY (€)
The amount is shown in this display.
FUNCTION OF THE SYMBOLS
The LCD displays have symbols which show the indicator's functioning status; you will find the description for each
symbol below.
SYMBOL
The battery is low (see section 3.2).
0   
The weight detected by the weighing system is near zero, within the interval of –1/4 ÷ +1/4 of the division.
~
The weight is unstable.
NET
The displayed weight is a net weight.
kg
Indicates the weight unit in use (kilogram).
LOCKED
The automatic unit price clear is disabled (see section 6.8)
€/kg
Indicates the price unit in use (per kilogram).
€/100g
Indicates the price unit in use (per hectogram).
M+
The total amount is greater than 0.
The displayed value is the return money.
6. OPERATION
6.1 AUTOMATIC ZERO UPON START-UP
The indicator has an "auto zero at start-up" function: in other words it means that if at start-up a weight within the
configured percentage (see F6 step, section 7) of the capacity is detected, it will be zeroed; if the weight is not within
this tolerance, the display shows "Err 4" and with a non approved instrument the present weight after a few instants,
while with an approved instrument "Err 4" is shown continuously.