Requirements To Meet Emc Directive - Mitsubishi GT14 User Manual

Graphic operation terminal
Table of Contents

Advertisement

5.2.1

Requirements to Meet EMC Directive

EMC Directives are those which require "any strong electromagnetic force is not output to the external.:Emission
(electromagnetic interference)" and "It is not influenced by the electromagnetic wave from the external.: Immunity
(electromagnetic sensitivity)".
Items  EMC directive thru  Grounding summarize the precautions to use GOT and configure the mechanical unit in
order to match the EMC directives.
Though the data described herein are produced with our best on the basis of the requirement items and standards of the
restrictions gathered by Mitsubishi, they do not completely guaranteed that all mechanical unit manufactured according
to the data do not always match the above directives. The manufacturer itself which manufactures the mechanical unit
must finally judge the method and others to match the EMC directives.
EMC directive
The standards of the EMC Directive are shown below.
Applied standard
Test standard
EN55011
Radiated noise
EN61000-4-2
Electrostatic immunity
EN61000-4-3
Radiated field AM
modulation
EN61131-2
EN61000-4-4
: 2007
Fast transient burst noise
EN61000-4-5
Surge immunity
EN61000-4-6
Conducted RF immunity
EN61000-4-8
Power supply frequency
magnetic field immunity
*1
The GOT is an open type device (device installed to another device) and must be installed in a conductive control panel.
The above test items are conducted in the condition where the GOT is installed on the conductive control panel and combined
with the Mitsubishi PLC.
*2
QP: Quasi-peak value, Mean : Average value
*3
The above test items are conducted in the following conditions.
30M-230MHz QP : 40dB V/m (10m in measurement range)
230M-1000MHz QP : 47dB V/m (10m in measurement range)
5 - 2
5. UL, cUL STANDARDS AND EMC DIRECTIVE
5.2 EMC Directive
Electromagnetic emissions from the
*1
product are measured.
Immunity test in which static electricity is
*1
applied to the cabinet of the equipment.
Immunity test in which field is irradiated
to the product.
*1
Immunity test in which burst noise is
applied to the power line and signal
*1
lines.
Immunity test in which lightening surge
*1
is applied to the product.
Immunity test in which a noise inducted
*1
on the power and signal lines is applied.
Test for checking normal operations
under the circumstance exposed to the
ferromagnetic field noise of the power
supply frequency (50/60Hz).
Test details
30M-230MHz QP:
30dB V/m (30m in measurement range)
230M-1000MHz QP:
37dB V/m(30m in measurement range)
80-1000MHz:10V/m
1.4-2GHz:3V/m
2.0-2.7GHz:1V/m
80%AM modulation@1kHz
Power line:2kV
Digital I/O(24V or higher): 1kV
(Digital I/O(24V or less))> 250V
(Analog I/O, signal lines)> 250V
Power line (between line and ground):
Power line (between lines):
Data communication port:
Power line: 10V
Data communication port: 10V
30 A/m
Standard value
4kV Contact discharge
8kV Aerial discharge
0.5kV
1kV
*2, *3
*2, *3
0.5kV

Advertisement

Table of Contents
loading

This manual is also suitable for:

Got1000

Table of Contents