Fitting the upper belt guard

.01.05
6
5
6
8
Fig. 8 - 05
8

Fitting the synchronizer

.01.06
1
Fig. 8 - 06
1
4
2
3
7
4
2
Installation and commissioning
If a large balance wheel is in
use, break off corner 1 of belt
guard part 3.
● Screw stop piece 2 onto belt guard part 3.
● Screw on belt guard part 3 with screws 4.
● Screw on belt guard part 5 with screws 6.
● Secure belt guard part 7 to the table top
8
using woodscrews 8.
8
● Push synchronizer 1 onto the shaft so
that stop 2 is standing in the slot on the
synchronizer (see arrow)
● Tighten screws 3.
● Connect the synchronizer plug to the
control box.
● Connect the synchronizer plug to the
adapter (see Chapter 8.02 Connecting
the plug connections and earth
cables).
● Adjust the synchronizer 1, see Chapter
3
8.05 Basic position of the machine.