DAITEM SH602AX Installation Manual
DAITEM SH602AX Installation Manual

DAITEM SH602AX Installation Manual

2 function remote keyfob with information feedback, bi-protocol 4 function remote keyfob with information feedback,8 function 4 key remote keyfob with information feedback

Advertisement

SJ608AX
SH602AX
SJ604AX
Contents
1. Introduction.................................... ................................. 1
2. Preparation..................................... ................................. 2
alarm control panel ................................ ........................ 3
4.1 Setting a command number ....................... ............... 3
®
wireless product................................. 5
®
wireless product............................... 5
on the remote control keyfob....................... .............. 5
Recommendations
The user must not attempt to access the device's in ternal parts, except areas described in this manual . If the user does
access these parts, the product guarantee will be c onsidered null and void and DAITEM shall not be hel d responsible for any
problems. Touching the device's internal parts and/ or electronic components can damage the product. Furthermore, the
device is designed in such a way that these parts a nd components do not need to be accessed for operation or
maintenance purposes.

1. Introduction

IMPORTANT
• Some functions are only available with control pa
panel keypad to check the version).
• Operational differences in relation to former ran
section at www.daitem.co.uk
The remote control devices SJ604AX and SJ608AX comb ine two radio protocols (TwinBand
control several product ranges.
The remote control device SH602AX operates only on
radio protocol.
• The keyfob can be used to control:
- the intrusion protection function of the alarm sy stem hence ensuring the protection of individuals
- latch/gate access points using the wireless doorp hone system (Optwin
- comfort applications with external receivers or t he remote-controlled socket (TwinBand
The keys can be personalised to adapt the commands
• Factory configuration of remote control keyfobs
The SJ608AX keyfob has a cursor (top and bottom pos ition) so that commands on each key can be doubled
providing up to 8 functions.
The commands allocated to keys are identical whatev er the position of the cursor (top or bottom).
2 function remote keyfob with information feedback
SH602AX:
bi-protocol 4 function remote keyfob
SJ604AX:
with information feedback
8 function 4 key remote keyfob
SJ608AX:
with information feedback
INSTALLATION MANUAL
®
®
radio) .......................... 3
nel versions 2.0.0 or later (enter
ges are described in the compatibility booklet avai
.
the TwinBand
6.2 Personalising the locking code ................. ................. 6
7. Three-colour LED operation...................... ................... 6
7.1 Information feedback........................... ....................... 6
7.2 Confirmation of receipt......................... ...................... 7
7.3 Protected or locked keys ....................... .................... 7
7.4 Remote control battery fault ................... ................... 7
8. Maintenance ..................................... .............................. 7
8.1 Changing the battery........................... ....................... 7
9. Technical data.................................. ............................... 8
®
radio protocol, it does not operate on the Optwin
®
), except for the SH602AX,
to the user's habits.
on the control
lable in the Daitem Installers
®
and Optwin
®
) allowing them to
(TwinBand
®
radio),
®
and Optwin
®
.)
hence
...... 6
®

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SH602AX and is the answer not in the manual?

Questions and answers

Summary of Contents for DAITEM SH602AX

  • Page 1: Table Of Contents

    The user must not attempt to access the device’s in ternal parts, except areas described in this manual . If the user does access these parts, the product guarantee will be c onsidered null and void and DAITEM shall not be hel d responsible for any problems.
  • Page 2: Preparation

    The keys are configured to issue the following commands: Factory configuration of keys Keyfob reference SH602AX Disarm SJ604AX Disarm Partially arm 1 Alert Cursor White in top Disarm Partially arm 1 Alert marker position SJ608AX Cursor Blue in bottom Disarm...
  • Page 3: Recognition Programming With A Twinband

    3. Recognition programming with a TwinBand ® alarm control panel This step enables radio recognition between devices: • the keyfob is recognised by the control panel, • the control panel is recognised by the keyfob (for managing control panel information feedback on the keyfob). To perform recognition programming, place the cursor in the top position for keyfob SJ608AX.
  • Page 4: Setting A Key To Arm Or Disarm Groups 1 To 8

    4. Set the parameters according to the sequence below. LED off about about about 10 s about 5 s about 10 s about 2 s pause 2 s pause 1.5 s press as shown red LED green LED To begin, Press briefly Press and hold Press the key...
  • Page 5: Radio Link Between The Remote Control Keyfob And An Optwin

    5. Radio link between the remote control keyfob and an Optwin ® wireless product This step only concerns the remote control devices SJ604AX and SJ608AX. IMPORTANT: An Optwin radio link can be created for a key programmed for a TwinBand command n°.
  • Page 6: Locking The Remote Control Keyfob Via A Code

    6. Locking the remote control keyfob via a code This step only concerns the remote control devices SJ604AX and SJ608AX. Locking the keyfob via a code prevents it from being used. The “code” corresponds to the keyfob being pressed 4 times (any key or keys).
  • Page 7: Confirmation Of Receipt

    LED indication table Command LED colour and status Meaning sent to: • Total/Partial or group DISARMING lights up steady GREEN for 1.5 s • Silent alarm flashes ORANGE Alarm control while the key flashes GREEN 3 times Total/partial or group DISARMING (with memory of alarm) panel is pressed then...
  • Page 8: Returning To The Factory Configuration

    • 8 Optwin ® radio commands a day Two-way radio link • TwinBand ® 400/800 MHz (SH602AX, SJ604AX, SJ608AX) • Optwin 868/870 MHz (SJ604AX, SJ608AX) ® Operating temperature - 10 ° C to + 50°C Degrees of mechanical protection...

This manual is also suitable for:

Sj604axSj608ax

Table of Contents