Details Of The Appliance; Ec Declaration Of Conformity; Standard Package; Description Of Appliance - Benchmark ZB 7-28 R 28 HE Installation And Servicing Instructions

Wall mounted condensing boiler for central heating
Hide thumbs Also See for ZB 7-28 R 28 HE:
Table of Contents

Advertisement

Details of the appliance

1
Details of the appliance
1.1

EC Declaration of Conformity

This appliance is in accordance with the applicable
requirements of the Gas Appliance Directive, Boiler Effi-
ciency Directive, Electromagnetic Compatibility Direc-
tive and the Low Voltage Directive.
PIN
Category
UK
Appliance Type
Table 1
1.2

Standard package

• Gas condensing boiler for central heating
• Wall mounting frame
• Fixings (screws etc.)
• Set of documentation for appliance
• Pre-plumbing manifold
• Condensate drain pipe.
4
CE-0085 BL 0507
II
2H 3P
C
, C
13
33
1.3

Description of appliance

• Wall-mounted appliance, siting not dependent on
room size
• Natural gas models are low-emission appliances
• Multi function display
• Bosch Heatronic control system
• Automatic ignition
• Modulating control
• Full safety systems incorporating Bosch Heatronic
with flame ionisation monitoring, solenoid valves and
temperature sensors
• Concentric flue/air duct with testing point for
CO
/CO
2
• Regulated speed fan
• Pre-mix burner
• Temperature control for central heating
• Safety temperature limiter in 24 V electrical circuit
• Three-speed central heating pump
• Relief valve, pressure gauge, expansion vessel, auto-
matic air vent
• Flue gas temperature limiter (105 °C)
• Condensate Trap
• Connecting possibility for S-Plan System.
6 720 611 443 GB (05.04)

Advertisement

Table of Contents