How The Door Sensor Or Shock Sensor Operates - PACH & COMPANY AeGIS 9100CR200 Installation And Programming Manual

Telephone access control systems aegis 9000 series
Table of Contents

Advertisement

HOW THE DOOR
SENSOR OR SHOCK
SENSOR OPERATES
Pach and Company
AeGIS 9000 Series
A Shunt (Mode 2)
Relay 2 and relay 1 are opened and closed simultaneously. You can use this feature for
the following applications:
• Open and close relay 2 (door 2) and relay 1 (door 1) simultaneously, remotely
or via a personal access code.
• Open relay 1 (door 1) and send the elevator down simultaneously, remotely or
via a personal access code. The elevator is connected to relay 2.
• Connect relay 2 to a light, an alarm device or a buzzer. The light will turn on if
door 1 is opened or an alarm or a buzzer will go off if door 1 is opened.
An Alarm Timer (Mode 3)
Relay 2 will be activated according to Function Code 29 if the following conditions are
true:
• Invalid access codes have been entered into the system for a specific number
of times programmed on Function Code "03".
• If relay 1 (door 1) is opened longer than the relay 1 open interval programmed
on Function Code "02".
Relay 2 can be connected to a light, an alarm device or a buzzer.
A CCTV Switch
Relay 2 can be use to turn "ON" a camera(s) to monitor a visitor(s) at the system.
Follow these steps to activate relay 2 as a CCTV switch.
Step 1 A visitor calls a tenant from the AeGIS 9000.
Step 2 The tenant answers the incoming call.
Step 3 The tenant must press number "6" (default setting) on his or her phone to turn
"ON" the camera and monitor the visitors at the system. The number can be
changed, see Function Code 43.
Step 4 When finished, press "7" (default setting) to turn "OFF" the camera. See
Function Code 43.
Step 5 Repeat step 3-4 if you need to turn the camera "ON" and "OFF".
The door sensor switch or shock sensor is an option (see figure 2.1 for wiring diagram).
Door sensor is available on door 1 or door 2, cannot be both. The AeGIS 9000 provides
the door sensor or shock sensor input. The door sensor switch is installed to notify or
warn an authorized person if a door is left opened or forced open or the system. The
shock sensor is notify an authorized person that the system is being vandalized. The
system will send a warning signal by calling the phone number programmed on Function
Code "09" or by turning an emergency light or a buzzer "ON" or the combination of the
two. Below is how the door sensor or shock sensor operates according to Relay 2 Mode
(Function Code "08").
MODE 1 (RELAY 2 AS DOOR CONTROL)
The system will make double beeps every 60 seconds if :
• Door 1 or Door 2 is still opened after the open interval is set on Function
Code 02 on relay 1 has expired.
• Or door 1or door 2 is forced open. If Function Code 09 is programmed to call
a phone number, the system will
• Make double beeps every 60 seconds.
• Call to the number programmed on Function Code 09 every 60
Chapter 4
SYSTEM'S OPERATION
Page 34

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents