Automatic Fan Speed
During Soft Dry Operation, use remote controller to select Auto Fan Speed mode.
Indoor Fan Speed is at "Lo-"
Lo-
Slo
OFF
Indoor
fan
T1
40
T2
70
10
ON
Compressor
Time Graph for soft dry operation
Intake Air temp
Cooling mode operation activated
1.5
Cooling mode operation stopped
Soft mode operation activated
1.0
Soft dry mode operation stop
Basic Time
Comp.
Indoor Fan
Outdoor Fan
Operation Indicator
4-way Valve
Operation status
a - c , p - r
c - p , r - u
e - f
j - l
q - t
Slo
OFF
6
OFF
a b c d e f
1
6
Super
Super
Super
Slo Slo
Low
Low
Low

Cooling Mode Operation

:
Soft Dry Mode Operation
:
Soft Dry Mode Operation Stopped
:
Compressor Test Operation Control
:
Anti Freezing Control
:
23
Lo-
Slo
OFF
OFF
T1
40
T2
70
10
ON
g
h i
j k l m n o p q
10 C
Evaporator
temperature
2 C
6
1
6
1
Super
Low
Slo Slo
Slo Slo
Slo Slo
Low
Time
CS-PA7DKD/CU-PC7DKD / CS-PC7DKD/CU-PC7DKD
r s t
u
o
o
4
6
Slo
Slo
Slo
Cooling mode operation
Soft Dry Mode operation
Operate
Stop